euroLINE 120
Translation (EN) of the original instructions (DE)
41 - 48
IEF-Werner GmbH | Wendelhofstraße 6 | DE-78120 Furtwangen | www.ief.de
G
en
er
at
ed
b
y:
R
ei
ch
el
t F
ra
nk
|
M
A
N
_E
N
_1131236_
eu
ro
LI
N
E120_
R
1d
.d
oc
8
Troubleshooting
Interference
Reason
Correction
Increased running noise
Nominal service life of guide carriage
exceeded
Complete exchange of the
guide carriages
Torque load on guide carriage too
high, causing play in the guide
carriage
Complete exchange of the
guide carriages
Motor coil does not run "freely" and
scrapes
Replace complete carriage unit
Error in power electronics or control
unit
Check, if required, exchange the
power electronics, control
Linear drive unit does not
move
Block from magnetic foreign parts in
the area of the magnets
Remove foreign parts,
Check motor coil for damage
Motor coil does not run "freely" and
blocks
Replace complete carriage unit
Plugs loose
Connect clamps U, V, W
Attention: Only when powered down
Encoder line defective
Replace encoder line
Measuring system defective
Check distance measuring head
↔
measuring tape; target = 0.15 mm
+0.2/-0.1
Replace complete carriage unit
Motor coil defective
Replace complete carriage unit
Guide carriage defective (stiffness,
block)
Replacement of the guide carriages,
if required of the guide rails
Error in power electronics or control
unit
Check components, replace if
necessary
Position loss
Measuring system defective
Check distance measuring head
↔
measuring tape;
target = 0.15 mm +0.2/-0.1
Replace complete carriage unit
Measuring tape contaminated /
damaged
Check components, replace if
necessary