9
Show down range
1~30
10
To control the effect of gate panel swing, the higher the value, the
earlier the braking
10
Self-check running
speed
1~9
3
The higher the value, the faster speed
11
Passing M
ode
0~2
0
0: Free passing mode:
delayed 1.5S when detection the
battery car.
1: memory function, N person card by N person passing.
2: one card and one person passing.( No battery car detection function)
12
Locking control
0~9
1
0: when triggers the last group of the IR, the gate will close.
1: After passing the last group of the IR, the gate will close.
2 ~ 9: After passing the last group of IR, the gate will close with a delay
(n-1 second)
13
Number of m
otors
0~1
0
0: Dual motor
1: Solo motor
14
Language
0~1
0
0: Chinese; 1: English
15
Stacking control
0~1
1
0: No rebound in case of resistance
1: Rebound in resistance
16
Stacking sensitivity
1~9
5
The higher the value, the higher the sensitivity
17
Retrograde control
0~1
1
0: Retrograde trigger does not close the gate, only voice alarm
1: The gate will be closed by retrograde.
18
Type of gate
0~3
0
0: swing gate (quick pass gate)
1: Cylindrical swing gate (supermarket swing gate) 2: Flap gate
3: Swing gate with unidirectional opening mode
19
Direction of arm when
power off
0~2
2
0: Turn off the switch in the left pass direction after power failure.
1: Turn the switch to the right after power failure.
2: The system automatically selects the power off direction according to the
current situation.
* The opening direction can refer to the direction indicated by the arrow of
the ceiling light board
20
Force of pushing the gate
1~9
5
The greater the value, the greater the force. Excessive force may
cause power restart. It is recom
m
ended to use the default value for
6.25A power supply
21
Voice of beak in control
0~1
1
0: there is no voice prompt w
hen the illegal intrusion event occurs.
1: There are relevant voice prom
pts when an illegal intrusion event occurs.
22
IR Signal re-trigger
delay
1~9
5
time=value*20ms (default 100m
s)
23
Direction of motor
operation
1~4
1
1: the main machine is turning forw
ard, the slave machine is
reversing;
2: the main machine reverses, and the slave machine forwards; 3: the main
machine is forward, the slave machine is forward;