10.  Operation 

 

      10-1. After applying a power to the SR10RW, buzzer sounds and 3 LED indicators turn on changing color 

red, green and red in order. And then 3 LED indicators turn off. Each LED indictor turns on red from 
the left in order again with beeping. (After applying a power, initialization status of the SR10RW is set 
to read card serial number when RF card is read.) 

 

      10-2. Until turning on green LED indictors with beeping one time, you make card read on the reader. After 

the  reader  transmits  card data  to access  controller,  LED  indicator  return  red  to  wait  for  next  card 
reading. 

             

If the reader transmits card data normally, all red LED indicators turn off  with  beeping one 
time and then each LED indicator turns on green from the left in order. If all LED indicators 
turn on green, they are changed red.                                                                                                                               

If not, buzzer sounds twice for retrying and red LED indicators flicker one time at all.                                                                                                                                               

In addition, buzzer sounds three times in the case of error. Also red LED indicators flicker one 

time at all.   

 

                                                                                                                                     

             

  If the unit doesn‟t operate normally, refer to „11. Troubleshooting‟ on this manual. 

 

10-3. LED Control 

You can control the LED of the device at your preference. 
Connect the LED Control Input wire (Yellow wire) to the NO port of controller relay output, and GND 
to the COM port. Set I/O of the controller; then you can change the color of the LED. While the LED 
control is working, the green LED stays on. 

This function is used for changing the LED color representing standby from red to green and applied 
to make various modifications according to the different I/O setting of the controller.   

For more information about the I/O setting of the controller, refer to the controller‟s user manual. 

 

10-4. Buzzer Control 

You can control the buzzer of the device at your preference.   

Connect the Buzzer Control Input wire (Blue wire) to the NO port of controller relay output, and GND 
to  the  COM  port.  Set  I/O  of  the  controller;  then  you  can  generate  beep  sound.  While  the  buzzer 
control is working, the product keeps sounding beep. The controller can use the I/O setting to set the 
buzzer controller so that it sounds the additional beep for authorized/unauthorized access. For more 

information about the I/O setting of the controller, refer to the controller‟s user manual. 

※ 

Caution: If you keep generating beep sound, the reader can’t read the card.

 

 

      10-5. Tamper Switch 
              If SR10RW is removed from the wall (or magnet) with the interval of more than 1cm, temper switch is 

operated, so 3 LED indicators turn on/off in order and buzzer keep sounding until no.7 of DIP switch 
is turned on.       

              If you want to set not to operate tamper switch, no.7 of DIP switch keep switching on. 
 
      10-6. Setting a “Smart Card Read / Write Software” 
              After applying a power, initialization status of the SR10RW is set to read card serial number. 

              To  set  SR10RW  as  access  control,  debt  meal  and  cashless  payment,  refer  to  user‟s  manual  of 

IDTECK PRG2000RW or Smart Card Read / Write Software.   

   

Summary of Contents for SR10RW

Page 1: ...User s Manual 13 56MHz MIFARE Contactless Smart Card Reader Writer ...

Page 2: ...ntifying Supplied Parts 5 6 Installation 6 7 Color Coded Wiring Table 8 8 Output Format 9 9 Wire Connection to Access Controller 11 10 Operation 12 11 Troubleshooting 14 12 FCC Registration Information 15 13 Warranty Policy and Limitation of Liability 16 14 How to Make RMA Request After Sales Service 17 ...

Page 3: ...perature specified in the specification Do not install the product with tools such as driver in hand when power is being supplied Do not drop liquid onto the product such as water and give the product a severe shock Do not place magnetic objects near the product Do not replace the wiring cables installed by experts Do not use the product under direct sunlight or in a heat producing place such as a...

Page 4: ...y controller using methods of RS232 and RS485 Three LED indicators of red and green inside Piezo buzzer sound will guarantee you accurate and reliable system operations 3 Features 13 56MHz MIFARE Contactless smart Card Reader Writer Read Range Up to 4 inch 10cm Read the Card which is issued by PRG2000RW Smart Card Read Write Programmer RS232 RS485 default 26 34bit Wiegand selectable Output Format ...

Page 5: ...le LED Indicator 3 Array LED Indicators Red Green Beeper Piezo Buzzer Operating Temperature 35 to 65 C 31 F to 149 F Operating Humidity 10 to 90 relative humidity non condensing Color Dark Pearl Gray Material Polycarbonate Dimension W x H x T 1 8 X 4 5 X 0 88 47mm X 115mm X 22mm Weight 120g 0 26lb Certification FCC CE KCC RoHS 5 Identifying Supplied Parts Please unpack and check the contents of th...

Page 6: ...talled on the wall then skip this step 6 2 Fixing a Tamper Magnet to the wall Attach a tamper magnet with tools such as double sided tape on the left of the bottom hole that you drilled in 6 1 Refer to the figure below 6 3 Fixing Reader Module Put reader cable into the center hole and fix the reader module using two 6 32 or M3 screws 6 4 Putting on the Cover Put on cover into the reader module and...

Page 7: ...d The typical read distance specification 2 4 inches at 12VDC refers to operation without metal in the vicinity of the Reader The read distance will be reduced if metal is installed nearby The SR10RW generate a magnetic field on all sides of the Reader Any metal that conducts electricity especially metal that contains iron steel or copper will interfere with the field and reduce the effective spac...

Page 8: ...r 12V Red Power Ground GND Black ABA Track II CP Out Orange Wiegand Data 0 Out ABA Track II Data Out Green Wiegand Data 1 Out ABA Track II Clock Out White Buzzer Control In Blue LED Control In Yellow Tamper Switch Out Gray RS232 TX Purple RS232 RX Brown RS485 A Pink RS485 B Cyan Cut out the tail connector before installation Two readers can simultaneously read the same badge or tag if the distance...

Page 9: ... 25 4byte ID number 0000000001 4 294 967 295 Bit 10 25 ID number 00000 65 535 Bit 26 Odd parity of bit 14 bit 25 Bit 34 Odd parity of bit 18 bit 33 2 Timing diagram 8 2 ABA Track II Magstripe output format 1 Data format for Card numbers 3 5V 0 5V 100uS 1mS Data 0 100uS 100uS Data 1 3 5V 0 5V 5V 5V 0V 0V Start Character 11010 Hex B ID number 1248P 0000000001 4294967295 low bit first odd parity last...

Page 10: ...V 3V Space 0 Mark 1 8 Data Bits 2 Stop Bits Indeterminate Region Data packet corresponding to ASCII character A Start Bit 0 1 0 0 0 0 0 1 0 LSB MSB 0V Start Character 11010 Hex B PIN 1char to 8char low bit first odd parity last LRC Zero bit Zero bit 10bit CLK RD1 Data RD0 1240us 940us 6000us 6000us CP 1544us ...

Page 11: ...11 9 Wire Connection to Access Controller ...

Page 12: ...is working the green LED stays on This function is used for changing the LED color representing standby from red to green and applied to make various modifications according to the different I O setting of the controller For more information about the I O setting of the controller refer to the controller s user manual 10 4 Buzzer Control You can control the buzzer of the device at your preference ...

Page 13: ...an 8 channel DIP switch and the switch is used to set Board ID RS232 RS485 Temper output and Initialization Switch Number Description No 1 5 Board ID Setting See the Board ID Example below No 6 RS232 or RS485 0 RS232 1 RS485 No 7 Tamper output enable disable 0 Enable 1 Disable No 8 Initialization For initialization switch on to 1 position and keep it about 1 5 seconds and then switch down to 0 pos...

Page 14: ...e is Serial Number and another is to encode desired data in sector and block Being the other confirm to same format of issued card and reader Contact card publisher or buying company to confirmation usage 4 Don t reading despite confirmation from step 1 to step 3 contact RMA center When sounding buzzer and being on LED faintly at impressed voltage Cause At installing reader whether use adapter les...

Page 15: ...tion is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation This equipment has been tested and found to comply with the limits for a Class B Digital Device pursuant to Part 15 of the FCC Rules These limits are designed to this equipment generates us...

Page 16: ...ECK does not and cannot know who is present what property is located where this product will be used it would be extremely difficult to determine the actual damages that may result from a failure of the product to perform as anticipated and the low price of this product is based upon the nature of the product provided and the limited liability that IDTECK assumes IDTECK IS NOT RESPONSIBLE FOR ANY ...

Page 17: ...oduct without RMA Code is not accepted If you have any questions or problems regarding the RMA services please contact us using the following contact information below Friendly representatives at IDTECK are always standing by to provide the best after sales services IDTECK Headquarter 5F Ace Techno Tower B D 684 1 Deungchon Dong Gangseo Gu Seoul 157 030 Korea Tel 82 2 2659 0055 Fax 82 2 2659 0086 ...

Page 18: ...td The specifications contained in this manual are subject to change without notice at any time 5F Ace Techno Tower B D 684 1 Deungchon Dong Gangseo Gu Seoul 157 030 Korea Tel 82 2 2659 0055 Fax 82 2 2659 0086 E mail webmaster idteck com ...

Reviews: