p.10
Installation and external connection
SR10/30V
Item
Cable Wiring
Power Supply Unit
Connect the DC+12V to the red line.
Connect GND to the black line.
Wiegand Connection
Connect the green line of the product to the Wiegand D0 input port of the
controller.
Connect the white line of the product to the Wiegand D1 input port of the
controller.
LED Control
To control the LED indicators, connect the yellow line to the output port
(relay) of the controller.
Buzzer Control
To control the built-in buzzer, connect the blue line to the output port
(relay) of the controller.
RS-232 Connection
Connect to the COM port of the PC. (Connect pin 2 of the DB-9
connector to the purple line; connect the GND (black) line of the device to
pin 5 of the DB-9 connector.)
Tamper Connection
Connect the pink line of the product to the GND terminal of the controller.
Connect the light yellow wire of the product to the GND terminal of the
controller.