Industrial 2 of 5 Settings:
Enable/Disable Industrial 2 of 5
If enabled, Industrial 2 of 5 symbology will be read, subject to the reading
restrictions specified by this set of options. If disabled, the data from the
symbology will be disregarded.
SELECTION CODE: F3
Industrial 2 of 5 Enable
A
Industrial 2 of 5 Disable
D
Fixed Length
Industrial 2 of 5 symbols are commonly printed in a fixed format contain-
ing a fixed number of characters. If this option is ON, the first Interleaved
2 of 5 symbol scanned after power up will set the length of any other
symbols scanned afterwards. If the succeeding scans do not match the
length of the first scan, the scan is rejected by the reader. Power must be
reset before an Interleaved 2 of 5 symbol of a different length will be
accepted.
SELECTION CODE: F3
Turn On Fixed Length
C
Turn Off Fixed Length
D
Check Digit
When Check Digit is selected, the reader takes the last character in the
decoded data stream as a check digit. It then calculates the correct check
digit for the remaining data and compares it to the last data character. If it
is the same, the data is accepted. If not, the data is rejected. With the
Calculate and Send Check Digit option, the reader will send the check
digit as part of the data stream. If the Calculate but Do Not Send Check
Digit option is selected, the reader will strip it from the data stream before
transmission. If the Check Digit is not calculated, the reader will assume
the last data character read from the symbol is part of the data stream and
will not make a comparison test.
SELECTION CODE: F3
Do Not Calculate Check Digit but Send Whole Data Stream
E
Calculate and Send Check Digit
F
Calculate but Do Not Send Check Digit
G
1 9
1 8
Interleaved 2 of 5 Settings:
Enable/Disable Interleaved 2 of 5
If enabled, Interleaved 2 of 5 symbology will be read, subject to the
reading restrictions specified by this set of options. If disabled, the data
from the symbology will be disregarded.
SELECTION CODE: F2
Interleaved 2 of 5 Enable
A
Interleaved 2 of 5 Disable
B
Fixed Length
Interleaved 2 of 5 symbols are commonly printed in a fixed format contain-
ing a fixed number of characters. If this option is ON, the first Interleaved
2 of 5 symbol scanned after power up will set the length of any other
symbols scanned afterwards. If the succeeding scans do not match the
length of the first scan, the scan is rejected by the reader. Power must be
reset before an Interleaved 2 of 5 symbol of a different length will be
accepted.
SELECTION CODE: F2
Turn On Fixed Length
C
Turn Off Fixed Length
D
Check Digit
When Check Digit is selected, the reader takes the last character in the
decoded data stream as a check digit. It then calculates the correct check
digit for the remaining data and compares it to the last data character. If it
is the same, the data is accepted. If not, the data is rejected. With the
Calculate and Send Check Digit option, the reader will send the check
digit as part of the data stream. If the Calculate but Do Not Send Check
Digit option is selected, the reader will strip it from the data stream before
transmission. If the Check Digit is not calculated, the reader will assume
the last data character read from the symbol is part of the data stream and
will not make a comparison test.
SELECTION CODE: F2
Do Not Calculate Check Digit but Send Whole Data Stream
E
Calculate and Send Check Digit
F
Calculate but Do Not Send Check Digit
G