VP 3600 User Manual
Page | 15
4.
Operation and Storage Environment
Item
Specification
Note
Operating Temperature 0 °C to 55 °C
•
Non-condensing.
•
Product operation temperature is limited to
the range for the reason of the constraint of
•
Li-Battery specification.
Storage Temperature
-20 °C to 60 °C
•
Non-condensing.
•
Product storage temperature is limited to the
range for the reason of the constraint of Li-
Battery specification.
Operating Humidity
5% to 95%
•
Non-condensing
Storage Humidity
5% to 95%
•
Non-condensing
•
Changes or modifications to the VP3600 not expressly approved by ID TECH could void the
user's authority to operate the VP3600.
5.
Other Agency Approvals and Compliances
•
CE (EN55022/EN55024, Class- B)
•
FCC (Part 15, Class-B)
•
RoHS (DIRECTIVE 2011/65/EU)
•
UL
•
REACH
•
PCI 5.x sRED
•
EMV Contact L1&L2
•
EMV Contactless L1
•
TQM
6.
Decommissioning SRED Devices
All PCI devices require proper decommissioning prior to device disposal in order to ensure the
protection of all sensitive financial card data. For instructions on decommissioning your device,
see
Decommissioning of SRED Devices
on the ID TECH Knowledge Base.