Page 65
Symbols
Code Programming ON
Code Programming OFF
Tools
Select Message Length
It is used to program the valid reading length of Interleaved 2 of 5. The engine
will not send barcode message to the Host, if the decoded data length does not
match the valid length.
Interleaved 2 of 5 Message Length is defined by
“
Min. Message Length
”
and
“
Max. Message Length
”
Interleaved 2 of 5
To set Min Message Length of Interleaved 2 of 5 as 8 bytes, and Max Message length as 12
bytes, read these programming codes:
1.
“
Code Programming ON
”
2.
“
Select Min Message Length
”
3. Digit Code
“
8
”
, see Digit Code Appendix (Pxxx)
4.
“
Save Programming
”
, see Digit Code Appendix (Pxxx)
5.
“
Select Max Message Length
”
6. Digit Code
“
1
”
7. Digit Code
“
2
”
8.
“
Save Programming
”
9.
“
Code Programming OFF
”
Min Message Length (default: 6)
【
Pro CMD
:
0405030
】
Max Message Length (default: 80)
【
Pro CMD
:
0405040
】
1D bar code Message Length should not exceed 127 bytes. If Max Message Length is
less than Min Message Length, it means the engine will only support barcodes of the two
lengths. If Max Message Length is equal to Min Message Length, the engine will only sup-
port barcodes of the length.