Page 30
RS232 Interface
RS232 Interface
Code Programming ON
Code Programming OFF
Tools
Parity Check
Parity check options should be the same on the engine and the Host.
Select Odd parity: If data has an odd number of 1 bits, the parity bit
»
value is set to 0.
Select Even parity:If data has an even number of 1 bits, the parity bit
»
value is set to 0.
Select No Parity Check and parity bit will not be sent.
»
**No Parity Check
【
Pro CMD
:
0101000
】
Even Check
【
Pro CMD
:
0101010
】
Odd Check
【
Pro CMD
:
0101020
】
Serial Port
Hardware Auto Flow Control
(
only for
2DScan
)
When enabled
,
2DScan
will decide if the data should be sent in accordance with CTS signal level. When it
is low level CTS signal, it means the serial port
’
s cache memory of receiving end (such as PC) is full and
2DScan
will not send data through RS232 until CTS signal is set to high level by receiving end.
When
2DScan
is not ready for receiving, it will set RTS signal to low level. When sending end (such as PC)
detects it, it could not send data to
2DScan
any more, otherwise the data will be lost.
When disabled, data
’
s sending and receiving through serial port will not be effected by RTS/CTS signal.
**Disable Hardware Auto Flow Control
【
Pro CMD
:
0104000
】
Enable Hardware Auto Flow Control
【
Pro CMD
:
0104010
】
Before enabling this function, please be sure that RTS/CTS signal line is contained in RS232
cable. If not, a RS232 communication error will occur.