4
REVISION A 09/15/14
82P33714/33814 EVALUATION BOARD
Board Default Frequency Output
Upon power-up, the following default frequencies will be available:
•
OUT1 = 25MHz
•
OUT2 = 125MHz
•
OUT3 = 156.25MHz
•
FRSYNC_8K_1PPS = 8kHz
•
MFRSYNC_2K_1PPS = 2KHz
Working with TimingCommand for Configuration
Use the following steps to setup the board using I
2
C and start the configuration of the board.
1. Connect the board as shown in
Figure 2
.
2. Press HW Reset button on the board to reset the device. This may not be necessary if the board is first powered up.
3. Start Timing Commander® software. You will see options of “New Setting File” and “Open Setting file”. For a new
configuration, select “New Setting File”.
Figure 3. Starting up Timing Commander GUI
4. After selecting “New Settings File”, a device selection window will pop up. In the window, choose the intended device in
the list, click the button at the lower right corner of the window to browse and open a personality file, then click OK.