You can use the following formula to calculate the mechanical flange back distance:
The tolerances for the position accuracy of uEye camera sensors are given in the Position
Accuracy chapter.
Calculating the flange back distance for USB uEye SE cameras
uEye
sensor
Sensor
glass
d
[mm]
Refractive
index (n
Glass
)
Distance
e
[mm]
x (no filter
glass)
[mm]
x (with filter
glass)
[mm]
Sensor
height
h
[mm]
CMOS
UI-121x-xx
0.550
1.52
1.225
18.94
19.29
2.460
UI-122x-xx
*V022)
0.400
1.49
0.475
18.13
18.48
1.450
UI-122x-xx
*V032)
0.550
1.50
1.400
19.46
19.81
2.500
UI-141x-xx
0.640
1.50
1.290
18.99
19.34
2.580
UI-144x-xx
0.640
1.50
1.330
18.99
19.34
2.580
UI-145x-Cx
0.525
1.50
1.270
18.97
19.32
2.480
UI-146x-Cx
0.550
1.49
1.250
18.96
19.31
2.375
UI-148x-xx
0.400
1.50
0.725
18.76
19.11
1.350
UI-154x-xx
0.525
1.50
1.270
18.97
19.32
2.480
UI-155x-Cx
0.550
1.50
1.45
19.16
19.51
2.500
UI-164x-Cx
0.550
1.50
1.45
19.16
19.51
2.500
CCD
UI-221x-xx
0.75
1.5
2.81
20.59
20.94
4.69
UI-222x-xx
0.75
1.5
2.81
20.59
20.94
4.69
UI-223x-xx
0.75
1.5
2.81
20.59
20.94
4.78
UI-224x-xx
0.75
1.5
2.81
20.59
20.94
4.83
UI-225x-xx
0.5
1.5
2.81
20.59
20.94
4.43
UI-231x-xx
0.75
1.5
2.81
20.59
20.94
4.78
UI-234x-xx
0.5
1.5
2.81
20.59
20.94
4.43
UI-241x-xx
0.75
1.5
2.81
20.59
20.94
4.78
*V022)
Sensor model MT9V022, identified b y b lack housing (BGA package)
*V032)
Sensor model MT9V032, identified b y b rown housing (technically identical with V022)
Calculation example: UI-154x-xx with IR-cut filter
(a = 17.526 mm, d = 0.525 mm, nGlass = 1.50, f = 1mm, nFilter = 1.53; see Filter Types table)