January 2020
13
Technical Manual: GigE uEye SE Rev. 4
For versions without front panel, two screws can be used to mount the PCB stack from the backside. The
following figure shows the mounting with S-board. To do this, remove first the transport lock (two nuts and
safety plate). Now the sensor board can be separated from the board stack and mounted. Then put the PCB
stack back on the sensor board and screw it together.
Fig. 5: PCB version with S-board
The following figure shows the mounting with L-board.
Fig. 6: PCB version with L-board
ESD protection
·
For optimum ESD protection, keep a clearance on all sides of 4 mm from unshielded housings. A smaller
clearance is possible with shielded housings.
·
The PCB should be mounted with the fixing screws on a base connected to the shield. If this is not possible,
an insulating connection must be ensured.
·
The connection cable should have a shield with low-resistance on both sides.