4
Dear
C
ustomer
, thank you for purchasing our product.
We assure you that properly operated
door
will impeccably serve
you for a long time.
CONTENT
1.
Regarding this instruction
1.1
Marking
2.
Safety instructions
3.
Mounting
4.
Operation and environmental conditions
4.1
Cleaning
4.2
Control
5.
Door maintenance and technical maintenance
6.
Malfunctions and elimination of defects
7.
Dismantling of door
8.
Documentation
9.
Disposal
1.
REGARDING THIS INSTRUCTION
This instruction was prepared in accordance to EC Directive 2006/42/
EC. The instructions for mounting, operating, maintenance and
dismantling the IDO-
PRO
(
HL)
doors are provided herein. Carefully
read this instruction and adhere to all of its requirements. Important
information about the product is submitted herein. Especially
adhere to the safety and warning instructions. In the event of doubts
regarding mounting and/or maintenance, contact UAB “IDOMUS”.
This instruction may be supplemented with other
instructions, for example, instruction for mounting passage doors or
electric automatic gear (if applicable).
All of the measurements are provided in millimeters, save
for those cases when indicated otherwise.
After mounting the doors, please ensure that the door’s
marking sticker “CE” is fi lled-out and sturdy glued to the doors.
Please keep this instruction in a safe place, near the doors.
Technical changes may be possible due to continuous development
of products.
2.
SAFETY INSTRUCTIONS
• Only a qualifi
fied
specialist (a competent person according to EN
12635) may perform the mounting, technical maintenance, repair
and dismantling works of the sectional garage doors.
•
In the event of door malfunctions (if the movement is
diffi cult or other malfunctions exist), for the inspection and repair of
them you must address a qualifi
ed
specialist.
•
The quali
fied
specialist must adhere to the
requirements national laws regarding work safety. When
performing mounting works, it is necessary to pay attention to
possible threats
defined
in EN 12604 and EN 12453.
•
Prior to starting door operation, you must check whether
the doors are off an impeccable mechanical condition and/or their
balance has been maintained, in order to manually control them
easily (as EN 12604 requires). Do not operate the doors, if damages
are clearly visible.
• EN 13241-1 defi nes the use area of IDO-
PRO
(
HL
) sectional doors.
3.
MOUNTING
Prior to starting the mounting works, carefully read all of the warning
and instructions contained herein in order to avoid any personal
injuries. Perform the mounting works only in accordance to the
procedure indicated herein, by having regard to these points:
• Prior to mounting the doors, check whether the door opening is
properly prepared and the building’s fl
oors
are bright enough;
•
For the duration of electrical works, ensure that
the electricity is turned off;
•
Mark the place of mounting works with a bright band in
order for other persons to keep their distance;
•
By having regard to the peculiarities of construction,
please check the suitability of parts supplied together with the
doors. A safe connection of door structure with the wall of the
building must be ensured;
•
When mounting, dismantling and repairing the doors
and performing all of drilling/cutting works, please wear protective
gloves, protective shoes and glasses (some parts may have sharp
edges);
•
The adding of additional parts or incomplete
assembly of the doors may impede the performance and safety of
the doors (it is prohibited to attach other manufacturers parts);
•
In these instructions, all of instructions for the assembly
of parts are depicted from the internal side, unless indicated
otherwise;
•
Use only work appropriate tools;
• Ensure proper ventilation and desiccation of the building. A proper
water outfall must be installed in the fl
oor
because, alternatively,
there’s a danger of corrosion;
•
Prior to starting the plastering, painting and cleaning works,
please ensure proper protection of the doors, because the
gypsum, cement, lime, paints and other construction materials
may damage the surface.
Please follow the mounting sequence indicated in
6 - 2
2
pages.
THE TENSIONING OF DOOR SPRINGS
High value torque is affecting the springs, which is why, in
order to avoid injuries, it is mandatory to ensure their safe tensioning!
Prior to tensioning the springs, the plane of the doors must be fi xed.
The CE sticker of the doors indicates approximate
tensioning speeds of the springs. When the springs are properly
tensioned, the plane of the doors stops after lifting it upwards.
When performing the technical maintenance, the tensioning of the
springs must be checked and, if necessary, they must be additionally
tensioned.
4.
OPERATION AND ENVIRONMENTAL CONDITIONS
For the user:
- Please ensure proper ventilation or desiccation of the building,
otherwise, danger of corrosion occurs;
- Prior to starting the plastering or painting works, please ensure the
proper protection of the doors, because the cement, gypsum and
other construction materials may damage the surface of the doors;
- Please protect the doors against aggressive and corrosive materials
(sprinkled salt, acids, alkalis, lime, potassium saltpeter stemming
from the bricks), because they aggressively react with the door
surface and sealing materials, and create a danger of corrosion;
- The protective fi lm must be peeled off from the doors within 30 days
from the mounting of them (this instruction is not valid for painted
doors).
Doors meant to be used in these conditions:
- Maximum outdoor temperature fl uctuation*: from -20 to +50 C°;
- Relative air moisture: 20 - 90 percent.
*Large temperature fl uctuations outside and inside may
cause the defects of sectional surface (bimetal effect), especially
this is valid for dark color segments, which is why, we recommend
avoiding them. The surface maintenance should be performed in
accordance to this instruction in order to avoid the risk of defects.
- Dangerous / important;
- Manual operation;
- Additional instructions.
EN
-
Residential automation
;
-
Industrial automation/
Chain drive
.
1
.
1
Marking
Summary of Contents for IDO PRO (HL)
Page 6: ...01 2 3 4 Angos plotis 125 mm Opening width 125 mm 125 6...
Page 7: ...5 6 7 5 8 7 999 8 8 7...
Page 10: ...n o n o p o qqqr s tuvwx r y z 10...
Page 11: ...11...
Page 12: ...12...
Page 13: ...13...
Page 14: ...14 7 5 7 6...
Page 15: ...15 8 8 1...
Page 16: ...16...
Page 17: ...m m m 0 m m 1 m 17...
Page 18: ...2 3 43 2 3 43 5 6 7778 9 8 5 18...
Page 19: ...19...
Page 21: ...21...
Page 22: ...22...
Page 23: ......
Page 24: ...UAB IDOMUS V Kr v s pr 129 Kaunas Tel fax 8 37 308 900 info idomus lt www idomus lt...