5. Allgemeine Beschreibung
Installation instructions Terra CL
16
1
2
3
4
5
6
7
8
9
10
11
12
13
1
2
3
4
5
Pos. 341
Pos. 342 (343)
Pos. 345 (346)
Pos. 344
Interior installation
In
te
rio
r ins
tall
a
tio
n
5.8.3. Accessories for corner installation
Pos. 341
.... Wall connection intake (for tight transfer)
Pos. 342
.... Weather shield grille intake
Pos. 343
.... Mesh grille intake
Pos. 344
.... Wall connection outlet (for tight transfer)
Pos. 345
.... Weather shield grille outlet
Pos. 346
.... Mesh grille outlet
5.8.4. Assembly Instr uctions -
Corner Installation
Wall connection is supplied separately. Vertical
connections must be affi xed fi rst. To do this, simply
remove the fi lm on the rear side. The cellular rubber
can then be affi xed fl ush with the external edge of
the heat pump. Additionally the horizontal elements
are also lined on the front. This will help ensure an
optimum seal.
Before the machine is positioned in the corner, a check
should be carried out to ensure that the wall opening
prepared by the customer has been insulated. The
machine can then be moved into the corner.
If there are any air gaps on the outlet or inlet open-
ings due to the ground being uneven, this can be
corrected using the adjustable machine feet.
Noise level
in the installation room depends on vari-
ous factors such as room size, absorption capacity,
refl ection, free noise propagation, etc. For this reason,
it is important that the heat pump is situated as far as
possible from noise-sensitive areas. A noise-insulating
door should be fi tted.
Signifi
cant pressure against the wall
should be avoided.
The heat pump may only be moved with