6 Precautions
Before connecting to external devices, follow the precautions below.
6.1 Installation
When installing the OPF-H2000, please observe the following precautions.
・
Do not stack or place the OPF-H2000 directly on top of another OPF-H2000
・
Do not block vent holes. To provide adequate ventilation, maintain sufficient clearances around the
OPF-H2000 (1.2 in. (30 mm) or more)
・
When the OPF-H2000 needs to be mounted in an enclosed space or an EIA rack without using IDK’s rack
mounting hardware (RM-SF, RM-SH), ensure that a sufficient ventilation/cooling system is provided to
keep the ambient temperature at 104°F (40°C) or lower. If inadequately vented, the product’s service life,
operation, and reliability may be affected.
Maintain adequate clearances (1.2 in. (30 mm) or more) as shown below
Bad example
Good example
Good example
[Fig. 6.1] Necessary clearances
6.1.1 Installing on wall or ceiling
You can install the OPF-H2000 on a wall or ceiling using the optional mounting plate (FP-100).