HDC-UHD Series Command Guide
62
@GAA
Alarm status
Getting
Command @GAA
Response @GAA, status_1, status_2, status_3, status_4, status_5
Parameter
status_1: Model number
Value
Description
HDC-TR121UHD
Model number
status_2: Version
Value
Description
V1.00R0
Version
status_3: The number of valid data
Value
Description
2
“2” (fixed)
status_4: Power voltage status
Value
Description
0
0: Normal
1: Abnormal
status_5: Internal temperature status
Value
Description
0
0: Normal
1: Abnormal
Getting
example
Command
Response
@GAA
@GAA,HDC-TH121UHD,1.00R0,2,0,0
Description Getting all alarm statuses
- Model number
: HDC-TR121UHD
- Version
: 1.00R0
- The number of valid data : 2
- Power voltage status
: Normal
- Internal temperature status : Normal