HDC-TH100-C/HDC-RH100-C User’s Guide 

15 

5.2.3  Twisted pair cable for extension 

The connector for a long-haul transmission is the same as the 8-core modular connector that is used for 

Ethernet. However, it cannot connect to Ethernet since the transmission method is not the same. 

To ensure the best performance, select and connect the proper twisted pair cable correctly. 
 

●  We recommend a Cat6 UTP/STP cable for the twisted pair cable between the transmitter and receiver.   

If using an STP cable, connect the FG connector to a ground source. Otherwise, the shielding feature 
does not work correctly. When using a UTP cable, we still recommend using the ground connector.   

●  For 50 m/ 164.04 feet or shorter transmissions, Cat5e UTP cable can be used. 

●  The shielded STP cables are less affected by interference or external noise than UTP cables. 

●  The maximum extension distance of Cat5e/Cat6 UTP/STP cable is the shortest distance of maximum 

extension distances of HDC transmitter, HDC receiver and sink device. 

●  For pin assignments apply T568A or T568B standards for straight through cabling. 

●  Do not give connection cables a strong pull. The allowable tension of the twisted pair cable is 110 N. 

●  Do not bend the connection cable at a sharp angle. Keep the bend radius four times of the cable diameter 

or larger. 

●  Do not tie the cable tightly; leave a space allowing the cable to move slightly. 

●  If you use the same cables, we recommended keeping a distance between the cables or not to place 

the cables closely in parallel. 

●  Keep the twisted pair cable as straight as you can. If you coil the cable, it is easily affected by noise. 

●  Do not place this product in an electrically noisy environment, since high-speed signals are transmitted. 

Particularly when you use a high-output radio around the HDC, video or audio may be interrupted. 

●  If the distance between the transmitter and receiver is 100 m/328.08 feet or less, cables can be joined 

using an RJ-45 plug coupler or wall outlet. Up to two cable couplers are allowed and couplers supporting 
Cat6A (10GBase-T) are recommended. 

●  The table below shows supported extension distance for each twisted pair cable category. Note that the 

distance may shorten depending on the actual environment. 
 

Category 

Extension 

distance 

Dot clock 

Remarks 

Cat5e 

50 m/164.04 ft. 

<=225 MHz 

For 50 m/164.04 ft. or longer, Cat6 is 

recommended 

Cat6 
 

100 m/328.08 ft. 

70 m/229.66 ft. 

>225 MHz 

(4K format) 

For 70 m/229.66 ft. or longer, Cat6 STP/Cat5e 

STP is recommended 

Cat5eSTP 
Cat6STP 

100 m/328.08 ft. 

 

Note:

 If there is a problem in the transmission path, video or audio may be interrupted. Please check the 

 

items above. If the problem still cannot be solved, shorten the length of the twisted pair cable. 

5.2.4  Precautions for RS-232C communication 

When designing a control program, please note the following points:   

●  For RS-232C communication, unnecessary data may be input to RS-232C signals when the HDC is 

turned off or the link is established. 

●  The control by RS-232C communication is not available until the link is established. 

 

 

Summary of Contents for HDC-RH100

Page 1: ...d carefully before using it and keep this manual beside this product IDK Corporation RS 232C LAN Tx Cat6 Tx for HDMI POWER LINK HDCP STATUS POWER LINK HDCP POWER LINK HDCP STATUS INPUT MAX 2M OUTPUT F...

Page 2: ...registered trademarks of HDMI Licensing LLC in the United States and other countries HDBaseT and the HDBaseT Alliance Logo are trademarks of the HDBaseT Alliance All other company and product names m...

Page 3: ...ency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely t...

Page 4: ...al injury if the warning is ignored or the equipment is handled incorrectly Indicates the presence of a hazard that may cause minor personal injury or property damage if the caution is ignored or the...

Page 5: ...y damage Set the power plug in a convenient place to unplug easily You can easily unplug in case of any extraordinary failure or abnormal situation and it also helps for unplugging when you do not use...

Page 6: ...r dusty place If the product is placed near humidifiers or dusty area it may cause fire or electric shock Do not block the vent holes If ventilation slots are blocked it may cause fire or failure due...

Page 7: ...paration 13 5 2 Precautions 14 5 2 1 Installation 14 5 2 2 Cabling 14 5 2 3 Twisted pair cable for extension 15 5 2 4 Precautions for RS 232C communication 15 5 2 5 DVI signals with copyright protecti...

Page 8: ...his User s Guide is common to both the transmitter and receiver You can download the latest version from IDK s website at http www idk co jp en index html HDC TH100 main unit HDC RH100 main unit AC ad...

Page 9: ...4 2 0 Digital video signals are transmitted without conversion to analog signals The HDC supports RS 232C serial bidirectional communication and LAN transmission HDC TH100 HDC RH100 Digital video HDMI...

Page 10: ...elay 10 s or less per 100 m 328 08 feet Others CEC pass through HDMI signals can be extended using twisted pair cables The AC adapter has a locking mechanism 1 For 70 m 229 65 feet or longer 4K format...

Page 11: ...range Lights when an HDC receiver is connected Blinks 0 5 second interval when the destination is in standby state LAN and RS 232C communications are available Turns off when no connection HDCP Yellow...

Page 12: ...e Lights when an HDC transmitter is connected Blinks 0 5 second interval when the destination is in standby state LAN and RS 232C communications are available Turns off when no connection HDCP Yellow...

Page 13: ...e please use one of the following cables Model number Length HDSS 005 0 5 m 1 64 ft HDSS 01 1 0 m 3 28 ft HDSS 02 2 0 m 6 56 ft Conversion cable HDMI DVI conversion cable Model number Length HDSS DMHM...

Page 14: ...install this product in closed space install an additional ventilation space in order to keep the ambient temperature at 40 degrees C 104 degrees F or less Exception Installing to IDK s Quarter rack...

Page 15: ...commended keeping a distance between the cables or not to place the cables closely in parallel Keep the twisted pair cable as straight as you can If you coil the cable it is easily affected by noise D...

Page 16: ...be determined only by connector shapes Example DVI signals are output even when a projector with an HDMI connector is connected Some source devices will check the EDID of the projector and if the aud...

Page 17: ...sing control devices such as PCs Projector Blu ray disk player PC AC adapter AC adapter HDMI HDC TH100 Transmitter Receiver HDC RH100 LAN RS 232C LAN RS 232C HDMI HDCP out HDCP out Twisted pair cable...

Page 18: ...0 16 SDA 8 TMDS Data0 Shield 17 DDC CEC Ground 9 TMDS Data0 18 5 V Power 19 Hot plug Detect N C No Connection Figure 6 1 HDMI Type A pin assignments 6 1 2 RJ 45 connector TIA EIA 568A TIA EIA 568B Pin...

Page 19: ...a cross cable RD TD N C N C N C N C GND RTS CTS Pin No 1 3 2 4 6 5 7 9 8 Signal RD TD N C N C N C N C GND RTS CTS Signal RX data TX data Ground TX request RX request HDC H100 IDK s product No connecti...

Page 20: ...to 8 channels Connector 1 RJ 45 1 female HDMI Type A Plug Play Pass through Twisted pair cables Cat6 UTP STP cable Cat5e UTP STP cable 6 Signal transmission distance 7 330ft approx 100 m using a Cat6...

Page 21: ...04 feet Cat6 cables are recommended 7 The maximum extension distances of Cat6 UTP STP cable and Cat5e UTP STP cable depend on the shortest length of any cable being used to connect the transmitter re...

Page 22: ...are appropriate to this device being used Are signal specifications of connected devices matched to each other Are settings of the sink device correct Are there any close objects that may cause noise...

Page 23: ...00 0765 Email idk_eng idk co jp URL http www idk co jp en index html Product information Support Arvanics Corporation 3 8 3 3F Yamato Higashi Yamato shi Kanagawa pref 242 0017 JAPAN TEL 81 46 259 6920...

Reviews: