Video

Image Sensor

1/2.9” CMOS

Max. Resolution

1920 x 1080

Scanning Mode

Progressive Scan

Lens type

Fixed-focal

Focal Length

f=4.0mm / f=2.8mm

Aperture

F2.15 / F2.0

Angular Field of View

H: 83° / V: 43° / D: 100.4° (f=4.0mm)
H: 109.24° / V: 59.37° / D: 128.58° (f=2.8mm)

Min. 

Illumination

DC-D4212R 

4.0mm

COLOR : 0.1 lux F2.15
B/W : 0 lux (IR LED ON)

DC-D4212R 

2.8mm

COLOR : 0.08 lux F2.0
B/W : 0 lux (IR LED ON)

Dynamic Range

D-WDR

Electronic Shutter Speed

Auto / Manual (1/30 ~ 1/10,000), Anti-Flicker, Slow Shutter(1 ~ 1/5,

 

1/7.5, 1/15)

Day & Night

IR cut filter with auto switch

IR Distance 

(LEDs)

DC-D4212R 

4.0mm

20m (2ea)

DC-D4212R 

2.8mm

20m (4ea)

Pan/Tilt/Lens 

Range

DC-D4212R 

4.0mm

Pan: -175° ~ 175°, Tilt: 0° ~ 70°, Lens: -90° ~ 90°

DC-D4212R 

2.8mm

Pan: -170° ~ 170°, Tilt: -5° ~ 67.5°, Lens: -109° ~ 109°

Network

Video Compression

H.265(MP), H.264(MP), M-JPEG

Bitrate Control

VBR/CBR

Max. Frame Rate

30fps : 1920 x 1080

Supported Resolution

1920x1080, 1280x720, 704x480, 640x360, 352x240

Multi-Video Streaming

Quadruple

Ethernet

RJ45(10/100BASE-T)

Summary of Contents for DC-D4212R

Page 1: ...Powered by DC D Series Installation Manual DC D4212R ...

Page 2: ...gh explanation about some functions may not be incorporated The manufacturer is not responsible for any problems resulting from the use thereof The information contained herein is subject to change without notice Revisions or new editions to this publication may be issued to incorporate such changes It is recommended that first time users of this network camera and individuals who are not familiar...

Page 3: ...ing storm or when it is left unattended and unused for long periods of time unplug it from the wall outlet and disconnect the antenna or cable system This will prevent damage to the equipment due to lightning and power line surges If thunder or lightning is common where the equipment is installed use a surge protection device 10 Overloading Do not overload wall outlets and extension cords as this ...

Page 4: ...s from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources Household users should contact either the retailer where they purchased this product or their local government office for details of where and how they can take this item for environmentally safe recycling Business users should contact their supplier and check the terms and conditions of ...

Page 5: ...er 8 Body 8 Factory Reset 9 Installation 10 Removing the Dome Cover 10 Installation 10 Closing the Dome Cover 11 Angle Adjustment 11 Dimension 11 Part 2 Camera Connection 13 With DirectIP NVR based Layout 13 With non DirectIP NVR based Layout 14 Part 3 Appendix 15 Troubleshooting 15 Specifications 16 ...

Page 6: ...to counter pre post event buffering and network delays for improved network recording reliability Remote monitoring via web browser or remote software Automatic web casting code HTML generation Up to 10 simultaneous remote monitoring connections IP filtering HTTPS SSL IEEE 802 1X and configurable user authority levels for greater security Network bandwidth limitation and MAT features for more effi...

Page 7: ...check inside the box to make sure all the following accessories are included External appearances and colors of the accessories may vary depending on the model DC D4212R 4 0mm DC D4212R 2 8mm Guide Pattern Network Camera Screws 2 ea Quick Guide ...

Page 8: ...odel Dome Cover DC D4212R 4 0mm DC D4212R 2 8mm Body DC D4212R 4 0mm 1 3 4 5 6 7 8 2 DC D4212R 2 8mm 1 3 4 5 6 7 8 2 1 Lens 2 Network Port 3 Wall Ceiling Installation Hole 4 Cable Access Hole 5 Bottom Cover 6 IR LED 7 Factory Reset Button 8 Status LED Lens Features a fixed focus lens ...

Page 9: ... during low lighting conditions Factory Reset Button Restores the camera s default factory settings For more information refer to the Factory Reset Status LED Indicates the system s operating status For more information refer to the LED Status Indications LED Status Indications LED Status Description Status LED Off Power not connected Flashing Upgrading On Powered on Factory Reset Only use the fac...

Page 10: ...allation Check the wall or ceiling to see if it needs to be reinforced The camera may fall off if the wall or ceiling is not strong enough to support its weight Install the camera in a shaded area If the camera is installed in direct sunlight it may be affected adversely Use the provided guide pattern to check the distance between the screw holes if necessary 1 Use the screws anchors provided with...

Page 11: ...l Rotation 2 Vertical Rotation Lens Rotation Used to adjust the lens rotation angle Turn the rotator in clockwise or counterclockwise direction Vertical Rotation Used to adjust the lens vertical angle Turn the rotator in clockwise or counterclockwise direction Horizontal Rotation Used to adjust the lens horizontal angle Turn the horizontal rotator in the clockwise or counterclockwise direction Dim...

Page 12: ...Part 1 Introduction 12 DC D4212R 2 8mm 130mm 81 4mm ...

Page 13: ...ng Monitor Out Network DirectIP NVR makes it easy to use cameras without extra network configurations Each camera can be controlled via the DirectIP NVR setup menu without any PC For detailed camera settings please see the camera setting pages of DirectIP NVR manual For users using the camera with DirectIP NVR connection do not need to consider contents in the camera operation manual Part 2 Camera...

Page 14: ...ote Recording IDIS Solution Suite Compact Control the camera over the network from software installed on a computer Ideal for using the camera over the network from a remote location The contents in the camera operation manual are only for users using the camera with non DirectIP NVR connection or VMS connection such as IDIS Solution Suite Compact ...

Page 15: ...s picking up an overly bright light source adjust the camera s position angle accordingly Video color appears incorrect Check the white balance settings If using the Auto option it may take some time for the white balance to be adjusted Images are blinking If the camera is pointed at the sun or a fluorescent lamp adjust the camera s angle away Lost the admin ID and password and unable to connect t...

Page 16: ... 2 8mm COLOR 0 08 lux F2 0 B W 0 lux IR LED ON Dynamic Range D WDR Electronic Shutter Speed Auto Manual 1 30 1 10 000 Anti Flicker Slow Shutter 1 1 5 1 7 5 1 15 Day Night IR cut filter with auto switch IR Distance LEDs DC D4212R 4 0mm 20m 2ea DC D4212R 2 8mm 20m 4ea Pan Tilt Lens Range DC D4212R 4 0mm Pan 175 175 Tilt 0 70 Lens 90 90 DC D4212R 2 8mm Pan 170 170 Tilt 5 67 5 Lens 109 109 Network Vid...

Page 17: ... 122 F Operating Humidity 0 90 Power Source PoE IEEE 802 3af Class 2 Power Consumption Max 4 6W Approval FCC CE External Dimensions Ø x H DC D4212R 4 0mm 130mm x 74 3mm 5 11 x 2 92 DC D4212R 2 8mm 130mm x 81 4mm 5 11 x 3 2 Weight Main Unit DC D4212R 4 0mm 0 21kg 0 46lb DC D4212R 2 8mm 0 225kg 0 49lb V2 0 ...

Page 18: ...IDIS Co Ltd For more information please visit at www idisglobal com ...

Reviews: