Idex TREBOR MAGNUM 620D PUMP Operation & Maintenance Manual Download Page 24

 

PAGE 24 

MAGNUM 620D PUMP OPERATION / MAINTENANCE MANUAL 

WARRANTY 

 

MAGNUM 620 PUMP 

TREBOR International, Inc. warrants to the purchaser of new equipment 
manufactured by TREBOR to be free from defects in material and workmanship 
when used for its intended purpose under normal operating conditions, and 
maintained according to the Operation/Maintenance Manual. 

TREBOR’s obligation under this warranty is limited to repairing or replacing, at 
TREBOR’s option and at the TREBOR factory, any part or parts thereof which 
shall, within 1 year after delivery thereof to the original purchaser, be 
demonstrated to TREBOR’s satisfaction to have been defective. This warranty 
may be transferred to subsequent owners.  The warranty period is based on the 
original ship date from the factory.  All warranty related freight costs shall be 
borne by the customer. 

Excessive wear to pump components caused by pumping abrasive solutions or 
chemicals, as well as damage caused by ingesting foreign objects shall not be 
covered by this warranty. 

This warranty shall not apply to any equipment which, in the judgment of 
TREBOR, shall have been repaired or altered outside TREBOR’s factory in any 
way, so as to affect its performance or reliability; subjected to misuse, negligence 
or accident; or used other than in accordance with TREBOR’s printed 
instructions. 

There are no terms, conditions or warranties, expressed, implied or 
statutory, of merchantability, fitness, capacity, or otherwise, of the goods 
ordered, other than, or different from, the warranty set forth above.   This 
warranty takes precedence over any other warranty, expressed or implied.

 

TREBOR neither assumes, nor authorizes any other party to assume for it, any 
liability in connection with said equipment except as set forth above. 

 

Summary of Contents for TREBOR MAGNUM 620D PUMP

Page 1: ...back of product PATENTS U S 09642426 U S 06106246 U S 05971402 U S 05370507 3 10 20 M620D C Phone 800 669 1303 or 801 561 0303 Fax 801 255 2312 e mail treborservice idexcorp com MAGNUM 620D PUMP Oper...

Page 2: ...entive Maintenance Record 12 4 2 RECOMMENDED SPARE PARTS 13 4 3 TOOLS 13 4 4 PARTS ILLUSTRATION 14 4 5 PARTS LIST 15 4 6 CLEAN UP 15 4 7 DISASSEMBLY 16 4 7 a Body Disassembly 17 4 7 b Head Disassembly...

Page 3: ...y Allow sufficient room for tubing connectors The pump mounts on a quick change base for easy installation The pump has an exhaust location on the backsides of the master and slave heads The exhaust l...

Page 4: ...e the pump NOTE 1 It is recommended that a filter be placed on the discharge side of the pump 2 Although extensive efforts are made to deliver pumps to our customers completely dry new pumps may conta...

Page 5: ...stainless steel or other rigid plumbing Available Options A Flare style tube adapter 1 2 and 3 4 B PFA tube stub out 3 4 C Pillar Super 300 3 4 OR 1 D PFA Weldable pipe 3 4 Figure 2 1 2 2 FLUID FITTI...

Page 6: ...PAGE 6 MAGNUM 620D PUMP OPERATION MAINTENANCE MANUAL Figure 2 2 NOTE See Surge Suppressor Operation Manual for detailed installation instructions...

Page 7: ...See Section 3 1 Refer to Troubleshooting Section 5 if pump fails to start ATTENTION Prolonged periods 5 minutes of dry running can damage critical internal pump parts CAUTION When handling potentially...

Page 8: ...PAGE 8 MAGNUM 620D PUMP OPERATION MAINTENANCE MANUAL Figure 3 1 Flow Performance NOTE Test information is based on specific conditions and limited sampling Use for general reference only...

Page 9: ...re vs Fluid Temperature Chart Recommended Maximum Pump Operating Levels NOTE 1 This graph is not representative of all operating conditions customer s specific application results may vary 2 Be sure t...

Page 10: ...ect to purchase a new Trebor pump If the customer chooses not to rebuild or replace the pump an evaluation charge will be required All returned pumps are to be shipped freight prepaid with a valid Pur...

Page 11: ...tall 30 Days 3 Months 6 Months 9 Months 12 Months 15 Months 18 Months 21 Months 24 Months Smart Pilot Assemblies R C Ring and Detent Legs R Muffler Media R Shaft Seal and Shaft R Check Balls and O Rin...

Page 12: ..._ ________________________________________ Date ________ Tech _____ Notes ________________________________________ ________________________________________ Date ________ Tech _____ Notes _____________...

Page 13: ...m 98001415 4 Check Ball 98002334 4 O ring PTFE 98003322 2 Shaft Seal AW072 1 Shaft AM083 2 Check Cap Seal AW017 1 Damper Port Seal 4 3 TOOLS The following tool kit is recommended as standard service e...

Page 14: ...PAGE 14 MAGNUM 620D PUMP OPERATION MAINTENANCE MANUAL 4 4 PARTS ILLUSTRATION...

Page 15: ...te PTFE 20 AW072 1 Shaft 2 PFA 21 98003322 2 Shaft seal 2 PTFE 22 98003395 4 Transfer Tube Fitting PP 23 98001072 2 3 8 Tube PFA 24 AW001 1 Body PTFE 25 98002334 4 O ring PTFE Check Valve 2 PTFE 26 98...

Page 16: ...cedures Reference the exploded view drawing and parts list for assistance in identifying components Immerse or flush the pump assembly using DI water and a neutralizing agent Install mounting fittings...

Page 17: ...e in the center of the shaft bore using the tip of a razor knife Take care not to damage the shaft bore NOTE Do not reuse seals Remove damper plug and seal using 3 4 pin tool 4 7 b Head Disassembly Un...

Page 18: ...own in Fig 2 Tilt the detent ring item 3 over one of the legs and align the groove on the inside of the detent ring with the end of the detent leg Tilt the other side of the ring down expanding it sli...

Page 19: ...d muffler assembly into head using 3 4 pin tool 4 8 b Pump Assembly NOTE Check sleeves that fit too tightly for easy installation should be placed in a freezer prior to assembly to assist insertion Bo...

Page 20: ...eat insertion process with the discharge sleeve check ball and O ring Repeat process for second check bore Replace seals and tighten check bore caps to 45in lbs Install seal and damper plug using 3 4...

Page 21: ...itial pump assembly Remove pump from the assembly fixture Place pump body with head down and place one diaphragm with V groove point away from the body Install pilot and pilot seat into heads Torque p...

Page 22: ...than 30psig Pump must prime and even cycling must be achieved Increase pressure to 60 psi and allow pump to run for 5 minutes Check for fluid leaks listen for air leaks and check for irregularity Prep...

Page 23: ...o high suction requirement Increase diameter of suction supply line reduces restriction Reduce output flow Ruptured perforated diaphragm Replace diaphragms Check bore caps leaking Tighten check bore c...

Page 24: ...warranty related freight costs shall be borne by the customer Excessive wear to pump components caused by pumping abrasive solutions or chemicals as well as damage caused by ingesting foreign objects...

Page 25: ...0303 Toll Free Number 800 669 1303 Fax Number 801 255 2312 Email treborinfo idexcorp com treborsales idexcorp com Address Trebor International 8100 South 1300 West West Jordan Utah 84088 U S A 7 2 TEC...

Reviews: