DOC No: 8540 REV E

5

DOC No: 8540 REV E

The following are used throughout this guide to indicate procedure that, if not followed 
correctly, may result in injury to personnel or damage to equipment.

Warnings are used to alert the reader to a procedure or practice, which if 
not followed correctly, could result in personal injury.

Limits of Use

6

Installation in Explosive and Fire Danger Zones

7

Description

7

Function

7

Unpacking and Storage

8

Assembly

8

Space Requirements

8

Location

9

Bulkhead Mounting

9

EMC Compatibility

9

Electrical Connection

10

Lead Assignments

12

Operation

13

Manual Control Adjustment

14

Magnet Decoupling

15

Maintenance

15

Fault Isolation

16

Technical Speci

fi

 cation

17-19

Notes

20-22

Table of Contents

CAUTION

NOTE

represents years of 

fl

 uid handling experience and we feel it is the 

fi

 nest product available 

of its type.

The product you have purchased was designed and constructed for use within designated 
limits and conditions. Staying within performance limits and following the guidelines given 
in this manual will result in excellent performance and maximum life.

Should you have a question or a problem, technical assistance is available worldwide.
Micropump products are designed for easy 

fi

 eld servicing with service kits and technical 

support available for all products.

The Purpose of this Guide...

is to provide information to enable suitably quali

fi

 ed technicians and 

fi

 tters to install, 

operate and maintain the Micropump EagleDrive and common pump/motor combinations.

Use the Guide...

when you have purchased a motor or pump/motor combination. This guide contains 
speci

fi

 c information for installation, operation, and maintenance of the EagleDrive and 

references some of the most common pump/motor combinations. This guide should 
be read in conjunction with the instructions provided with your speci

fi

 c pump. General 

information is given on installation within a system, but reference should always be made 
to instructions provided with ancillary equipment when installing the unit.

Abbreviations

The following abbreviations are used in this guide:

°C 

Degrees Celsius 

 

°F 

Degrees Fahrenheit 

EMC 

Electromagnetic Compliance 

DC 

Direct Current

LVD 

Low Voltage Directive 

IOM         Installation, Operation and Maintenance Manual
Max 

Maximum 

  Min 

Minimum

RPM 

Revolutions Per Minute  

SELV 

Safety Electric Low Voltage

Volt(s) 

  W 

Watt(s)

Warning - Hot Surface is used to alert the reader to a procedure or 
practice, which if not followed correctly, could result in personal injury 
due to contact with a hot surface.

Cautions are used to alert the reader to a procedure or practice, which 
if not followed correctly, could result in damage to the pump, motor, or 
ancillary equipment.

Notes are used to highlight important information that may assist the reader in 
carrying out a procedure or in understanding the text.

Safety

Your Micropump Product...

Summary of Contents for MICROPUMP EagleDrive DEELE

Page 1: ...NSTALLATION OPERATION AND WARRANTY INFORMATION EAGLEDRIVE TM EagleDriveTM DEMSE EagleDriveTM DEELE Without Enclosure Without Enclosure DEMSN DEELN CALL TOLL FREE 877 742 2878 FOR SALES AND SUPPORT Return to BurtProcess com ...

Page 2: ...and power cables The Power Supply Assembly means only the printed circuit board and the electronic or mechanical components located inside or on the power supply enclosure and the Pump head Assembly means all other parts of the product including but not limited to the rotor No warranty of any kind is made or shall be imposed with respect to any pump or parts 1 that have not been properly installed...

Page 3: ...his Guide is to provide information to enable suitably qualified technicians and fitters to install operate and maintain the Micropump EagleDrive and common pump motor combinations Use the Guide when you have purchased a motor or pump motor combination This guide contains specific information for installation operation and maintenance of the EagleDrive and references some of the most common pump m...

Page 4: ...low risk of external damage Hot Surfaces Under some operating conditions surface temperatures can exceed 90 C 195 F Do not touch products while operating Do not touch within 30 minutes of system shutdown to allow surfaces to reach safe handling temperature Description The EagleDrive is a brushless DC motor with integrated controller specially designed to be electromagnetically coupled to a variety...

Page 5: ...rews 4 supplied with the EagleDrive Torque screws to 0 8 N m 7 in lbs Loose bolts may result in pump motor misalignment Tighten bolts appropriately Pump motor misalignment may result in weakening the sealing of the enclosure Drive housing seal described below is required for IP55 rating Assembly Unpacking and Storage The product should be located with the inlet below or even with the liquid level ...

Page 6: ...tage source and the frequency counter if used will be forced to the same ground reference when connected to the EagleDrive Ensure only one earth ground is used to avoid ground loops Using The Tachometer Output The tachometer output can be monitored using a frequency counter The tachometer output is 0 5V square wave pulse that occurs twice per pump drive revolution To convert the tachometer output ...

Page 7: ...te the magnets inside the pump Ensure pump is correctly attached to EagleDrive 1 0 Internal Short Disabled Drive components have failed Reset EagleDrive by disconnecting and restoring power supply connection if problem persists contact Micropump for a replacement 0 1 Low Load Current Operating Drive components have failed Reset EagleDrive by disconnecting and restoring power supply connection if p...

Page 8: ... the EagleDrive by first setting the external control signal input to the minimum value then switch off the power supply Check that the unit runs down in a steady manner Close the inlet and discharge valves Drain the pump if it is to be shut down for long periods or installed in areas where the liquid may freeze Refer to the Maintenance section for instruction on draining Extended periods of dry r...

Page 9: ...ump periodically The pump cannot be drained completely a certain amount of liquid will remain in the magnet cup area Ensure that the pump is either flushed with a suitable flushing agent or precautions are taken against the effect of any remaining liquid during servicing When the pump has been handling flammable toxic or hazardous fluid the pump internals must be properly decontaminated by suitabl...

Page 10: ...r Out lead is connected to the positive input of the frequency counter Check that the common lead of the frequency counter is connected to the motor Common lead Check leads to ensure no short circuits are present Motor is stopped Ensure proper voltage has been applied to motor power leads Ensure proper control input is applied to Control Input lead Ensure control power supply common is connected t...

Page 11: ... Current Nominal Voltage 25 C Ambient 2 9A 24 VDC Speed Control 0 to 5 VDC Tachometer Out 0 to 5 VDC square wave 2 pulse per revolution Thermal Shutdown 135 C Thermal Restart 120 C Storage Temperature 40 to 135 C Maximum Ambient Operating Temperature 85 C at max load Reversible Yes Weight 0 5 kg Power Output Nominal 52 W Model DEELE EagleDrive Pump Configurations EAGLEDRIVETM DEMSE GA Series GJR S...

Page 12: ...98684 USA Tel 1 360 253 2008 Fax 1 360 253 8294 E mail info micropump idexcorp com Web www micropump com To purchase pumps parts or receive further information contact your local Micropump distributor or contact Micropump directly MICROPUMP AND THE MICROPUMP LOGO ARE TRADEMARKS OF MICROPUMP INC Your Micropump Distributor Is ...