Flow rate should always be adjusted by controlling motor speed where 
possible. Ensure that overpressure does not occur in the discharge pipe. 
NEVER throttle 

fl

 ow by an inlet valve.

Starting or running the pump with the discharge valve closed may result 
in overpressure in the discharge pipe.

Post Start-up Checks
Once the pump has started, carry out the following checks:
1. Check that the pump and motor operate smoothly and are free from vibration.
2. Check the inlet and discharge 

fi

 ttings are free from leaks.

Operation

Start-up Procedure
Before starting the pump ensure that any valves in the inlet or discharge lines are open 
and that any inlet 

fi

 lters are clean and free from obstruction.

1.  Set the external control signal input to minimum value (0 VDC.)
2.  Set the power supply (12 VDC to 36 VDC) to ON. With the control input set to 0V or < 

3% PVM VDC the pump will show a nominal 25mA to 100mA current draw and will not 
turn.

3.  Adjust the control signal input to the required level. Current demand will rise and fall as 

the pump load and speed varies.

Once started the pump should prime if it has not already been 

fi

 lled with 

fl

 uid. If the pump 

fails to prime, stop the pump and 

fi

 ll the pump head with liquid.

Shut-down Procedure
Switch off the EagleDrive by 

fi

 rst setting the external control signal input to the minimum 

value, then switch off the power supply. Check that the unit runs down in a steady 
manner. Close the inlet and discharge valves. Drain the pump if it is to be shut-down for 
long periods or installed in areas where the liquid may freeze. Refer to the Maintenance 
section for instruction on draining.

Extended periods of dry running may result in permanent damage to the 
pump and may cause surface temperature to exceed the operating 
temperature of the pump. Ensure that the pump head temperature does 
not exceed the 

fl

 ash point temperature of the 

fl

 uid or area. Shut down 

pump for a no 

fl

 uid condition.  Shut down the pump for a no 

fl

 ow condition.

CAUTION

CAUTION

Ensure the pump head temperature does not exceed the 

fl

 ash point 

temperature of the 

fl

 uid or area.

Do not operate EagleDrives in two-wire mode. Control with input connected to 
mains voltage. Contact your local Micropump distributor or contact Micropump 
directly about a special pump/motor unit with regard to your speci

fi

 c system 

needs.

To maintain protection of internal drive controller, your external resistor 
should be 

fi

 tted with 

appropriate protection.

4-20mA Control Input

4-20mA Control
Install a 250 Ohm resistor across the yellow Speed Input and black Common lead wires. 
Applying current across this resistor will result in a commanded proportional speed from 
the Eagle Drive.

CAUTION

Recommended Resistor

VISHAY P/N PTF65250R00AYBF

Summary of Contents for MICROPUMP EagleDrive DEELE

Page 1: ...NSTALLATION OPERATION AND WARRANTY INFORMATION EAGLEDRIVE TM EagleDriveTM DEMSE EagleDriveTM DEELE Without Enclosure Without Enclosure DEMSN DEELN CALL TOLL FREE 877 742 2878 FOR SALES AND SUPPORT Return to BurtProcess com ...

Page 2: ...and power cables The Power Supply Assembly means only the printed circuit board and the electronic or mechanical components located inside or on the power supply enclosure and the Pump head Assembly means all other parts of the product including but not limited to the rotor No warranty of any kind is made or shall be imposed with respect to any pump or parts 1 that have not been properly installed...

Page 3: ...his Guide is to provide information to enable suitably qualified technicians and fitters to install operate and maintain the Micropump EagleDrive and common pump motor combinations Use the Guide when you have purchased a motor or pump motor combination This guide contains specific information for installation operation and maintenance of the EagleDrive and references some of the most common pump m...

Page 4: ...low risk of external damage Hot Surfaces Under some operating conditions surface temperatures can exceed 90 C 195 F Do not touch products while operating Do not touch within 30 minutes of system shutdown to allow surfaces to reach safe handling temperature Description The EagleDrive is a brushless DC motor with integrated controller specially designed to be electromagnetically coupled to a variety...

Page 5: ...rews 4 supplied with the EagleDrive Torque screws to 0 8 N m 7 in lbs Loose bolts may result in pump motor misalignment Tighten bolts appropriately Pump motor misalignment may result in weakening the sealing of the enclosure Drive housing seal described below is required for IP55 rating Assembly Unpacking and Storage The product should be located with the inlet below or even with the liquid level ...

Page 6: ...tage source and the frequency counter if used will be forced to the same ground reference when connected to the EagleDrive Ensure only one earth ground is used to avoid ground loops Using The Tachometer Output The tachometer output can be monitored using a frequency counter The tachometer output is 0 5V square wave pulse that occurs twice per pump drive revolution To convert the tachometer output ...

Page 7: ...te the magnets inside the pump Ensure pump is correctly attached to EagleDrive 1 0 Internal Short Disabled Drive components have failed Reset EagleDrive by disconnecting and restoring power supply connection if problem persists contact Micropump for a replacement 0 1 Low Load Current Operating Drive components have failed Reset EagleDrive by disconnecting and restoring power supply connection if p...

Page 8: ... the EagleDrive by first setting the external control signal input to the minimum value then switch off the power supply Check that the unit runs down in a steady manner Close the inlet and discharge valves Drain the pump if it is to be shut down for long periods or installed in areas where the liquid may freeze Refer to the Maintenance section for instruction on draining Extended periods of dry r...

Page 9: ...ump periodically The pump cannot be drained completely a certain amount of liquid will remain in the magnet cup area Ensure that the pump is either flushed with a suitable flushing agent or precautions are taken against the effect of any remaining liquid during servicing When the pump has been handling flammable toxic or hazardous fluid the pump internals must be properly decontaminated by suitabl...

Page 10: ...r Out lead is connected to the positive input of the frequency counter Check that the common lead of the frequency counter is connected to the motor Common lead Check leads to ensure no short circuits are present Motor is stopped Ensure proper voltage has been applied to motor power leads Ensure proper control input is applied to Control Input lead Ensure control power supply common is connected t...

Page 11: ... Current Nominal Voltage 25 C Ambient 2 9A 24 VDC Speed Control 0 to 5 VDC Tachometer Out 0 to 5 VDC square wave 2 pulse per revolution Thermal Shutdown 135 C Thermal Restart 120 C Storage Temperature 40 to 135 C Maximum Ambient Operating Temperature 85 C at max load Reversible Yes Weight 0 5 kg Power Output Nominal 52 W Model DEELE EagleDrive Pump Configurations EAGLEDRIVETM DEMSE GA Series GJR S...

Page 12: ...98684 USA Tel 1 360 253 2008 Fax 1 360 253 8294 E mail info micropump idexcorp com Web www micropump com To purchase pumps parts or receive further information contact your local Micropump distributor or contact Micropump directly MICROPUMP AND THE MICROPUMP LOGO ARE TRADEMARKS OF MICROPUMP INC Your Micropump Distributor Is ...

Reviews: