20
Programming Functions
Fs1=
is the full scale value for the sensor connected to
the converter. There are four fields to select to set this
parameter. From left to right these are:
1. Volume Unit of Measure (
gal
)
2. Type of Unit (
/
)
3. Time Unit of Measure (
m
)
4. Numeric Value of Full Scale Measure (
099.99
)
STEP 1
: With the selection bar on
Fs1
, press
to
gain access to the four fields. Move the cursor to “
/
”
using the
key and press the
key to change the
type of unit of measure. The options are metric, British
or American, mass, or volume units.
When scrolling through the four options, the following
will be displayed:
oz/
:select for non-metric mass units
l/
:select for metric volume units
kg/
:select for metric mass units
in³/
:select for non-metric volume units
Scroll to the desired option and press
to accept the
value,
to move to the next field, or
to move to
the previous field.
STEP 2
: Selection of the “
/
” field changes the options for
the unit of measure field. Selecting the time base field
changes the available options of the unit of measure field
as well. Therefore, after selection of the “
/
” field, set the
time base field by pressing
once.
The options for time base are:
s
:per second
m
:per minute
h
:per hour
d
:per day
Make the selection and press
twice to move to the
first field to set the unit of measure. The options available
are determined by the rate base and type of unit already
selected. The following tables contain the available units
of mass and volume.
STEP 3
: With the three fields selected, proceed to
program the full scale value. Press
to move to the
first digit of the numeric value representing full scale for
the sensor connected. Use
to scroll through 0-9 for
each position. When the full scale value has been
entered, press
to exit the field.
NOTE
: The converter accepts any kind of combination
of units of measure satisfying both the following
conditions:
•
Numeric field value i s
≤
99999.
•
1
/
25
fs
max
≤
numeric field value
≤
fs
max
.
Where fs
max
is the maximum full scale value
corresponding to the sensor, equal to a 10m/sec liquid
velocity.
NOTE
: It is recommended that this value be set
approximately 10% above the desired maximum flow
rate. If the Fs1 value is reached, an alarm appears on
the display: “
FLOW RATE>FS
”.
2-SCALES
“kg/” Selection Options
g
grams
kg
kilograms
t
tonnes
“in³/” Selection Options
in³
cubic inches
gal
American gallons
GAL
British gallons
ft³
cubic feet
bbl
standard barrel
BBL
oil barrel
yd³
cubic yards
kgl
1000 American gallons
KGL
1000 British gallons
“oz/” Selection Options
oz
ounces
lb
pounds
ton
short tons
“l/” Selection Options
l
litres
dm³
cubic decimeters
dal
decaliters
hl
hectoliters
m³
cubic meters
cm³
cubic centimeters
ml
milliliters
099.99
1.000
1.00000
1.00000
0050.00
0050.00
01.0000
2-SCALES
Fs1=gal/m
Tot.MU=gal
Imp1=gal
Imp2=gal
Tpul1=ms
Tpul2=ms
Sg=kg/dm³