Idex HALE SPV Installation And Maintenance Manual Download Page 5

S

emi-Automatic 

P

riming 

V

alve

1

WARNING:

  Parts under spring tension can

become projectiles and cause serious injury.
When removing or installing these parts make
sure they are restrained and spring tension is
released slowly.

WARNING:

  Disconnect or turn-off master

battery switch prior to service of the Hale SPV
electrical components.  Make sure there is no
power at the primer solenoid before starting
service procedures.

WARNING:

  Any electrical system has the

potential to cause sparks during installation,
service or repair.  Take care to eliminate
explosive or hazardous environments during
installation, service or repair.

WARNING: 

 Check all hoses for weak or worn

conditions after each use.  Ensure that all
connections and fittings are tight and secure.

WARNING:  

Use only pipe, hose, and fittings

from the priming pump vacuum connection to
the Hale SPV vacuum connection rated for 29 in
(737 mm) Hg vacuum.

CAUTION:

  Make sure the Hale SPV is located

higher than the pump body allowing water to
drain from the vacuum hose.

SAFETY

IMPORTANT NOTICE:

  Before attempting installation and maintenance of the Hale SPV read and

follow all safety precautions listed below.  The warnings and cautions listed are necessary for the
safe installation or maintenance of the Hale SPV.  When developing departmental apparatus
maintenance procedures make sure the warnings and cautions are incorporated as written.

Summary of Contents for HALE SPV

Page 1: ...rtant to follow the instructions on care and operation Proper use and good preventive maintenance will lengthen the life of your unit ALWAYS INCLUDE THE UNIT SERIAL NUMBER IN CORRESPONDENCE Hale Produ...

Page 2: ......

Page 3: ...o copies of the Hale SPV manual to the end user of the equipment For additional manuals contact Hale Products Inc at 610 825 6300 Ask for Manual P N 029 0020 33 0 TABLE OF CONTENTS SECTION PAGE 1 SAFE...

Page 4: ......

Page 5: ...stallation service or repair WARNING Check all hoses for weak or worn conditions after each use Ensure that all connections and fittings are tight and secure WARNING Use only pipe hose and fittings fr...

Page 6: ...button is released Once push button is released the priming pump stops running allowing the Hale SPV to close for normal pump operation The Hale Semi Automatic Priming Valve Hale SPV shown in figure 1...

Page 7: ...mp body Components that are included with this option and shipped with the midship pump are the Push button Switch Panel Placard and Installation Manual When completing the apparatus installation of t...

Page 8: ...the gearbox All that remains after the midship pump is mounted on the apparatus frame is to install the panel placard and push button on the pump operator panel and make the electrical connections fro...

Page 9: ...hole in the panel 3 Remove the push button switch from the packaging and install the locknut on the mounting neck 4 Refering to figure 3 Insert the push button switch through the 0 64 inch 16 mm diam...

Page 10: ...card push button switch Use material thickness and fastening devices that leave a flat surface 6 Connect electrical leads to the momentary contact push button 7 Locate the priming valve flange on the...

Page 11: ...hose connection on the Hale SPV to the priming pump connection Use hose with 3 4 inch 19 mm inside diameter that is rated for 29 in 737 mm Hg vacuum Aeroquip 2556 12 or equal Make sure the hose is rou...

Page 12: ...hole on the diaphragam cover will be in the down Hale SPV Installation with Universal Mounting Adapter When installing the Hale SPV assembly with a universal mounting adapter use the following proced...

Page 13: ...on rated for 29 in 737 mm Hg vacuum 8 Attach 3 4 inch 19 mm ID vacuum hose from the hose connection on the Hale SPV to the priming pump connection Use hose with 3 4 inch 19 mm inside diameter that is...

Page 14: ...service with a minimum of preventive maintenance Performance degradation can result from a ruptured diaphragm or worn seat on the valve A Hale SPV repair kit that contains a manual seal ring valve and...

Page 15: ...With the Hale SPV on a stable surface place the diaphragm plate over the spring and press down to compress spring While holding diaphragm plate down with spring compressed install 10 24 x 1 2 inch lo...

Page 16: ...0231 00 0 DIAPHRAGM COVER PAINTED 1 EA 8 046 0121 00 0 DIAPHRAGM 5 3 8 IN DIA 1 EA 9 018 1004 32 0 SCREW 10 24 X 1 2 IN LG 1 EA 10 005 0021 00 0 SPV DIAPHRAGM PLATE 1 EA 11 042 0081 00 0 VALVE RETURN...

Page 17: ...e pump and disassembled REPAIR KIT PART NUMBER 546 1680 00 0 The repair kit contains the following components Refer to the exploded view on the previous page for parts identification ITEM PART NUMBER...

Page 18: ...UALITY COURSE OF DEALING USAGE OF TRADE OR PATENT INFRINGEMENT FOR A PRODUCT MANUFACTURED TO ORIGINAL BUYER S DESIGN AND SPECIFICATIONS EXCLUSIVE REMEDIES If Buyer promptly notifies HALE upon discover...