75
E.
Remove flowmeter from piping/manifold/spacer.
F.
Note flowmeter orientation (specifically – locator pin).
Installation
A.
Lubricate flowmeter O-rings. (See Table 6.)
B.
Install new flowmeter.
(Orient flowmeter so locator pin fits into adaptor/saddle clamp.)
C.
Install retaining nut over flowmeter (thread electrical cable thru nut) and hand
start threads.
D.
Using 2-1/4-in wrench, tighten retaining nut.
E.
At discharge valve motor controller, connect electrical cable according to tags.
F.
Install cable ties cut to R&R flowmeter as noted.
G.
Close SAM panel(s).
Perform the applicable calibration (or reset) procedures IAW paragraph 5.2.3, page 178.
4.7.3
Pressure Sensors/Transducers
The SAM system utilizes two (2) types of pressure transducer: high pressure Hale transducers
(up to 300 PSI) are used to take individual pressure measurements for all the discharge valves
and for the pump intake and pump discharge pressure measurements; Hale low pressure trans-
ducers are used to detect prime and measure the various tank levels (ITL-40). Both pressure
sensors appear similar and have the same pin layout (see Figure 48).
Figure 48. Hale Pressure Sensor/Transducer And Pin Layout
The sensors are used for multiple purposes within the SAM system: individual discharge valve
pressure (displayed on the SAM Control Center) see Table 29; pump intake and discharge pres-
sure (master pressures) see Table 30; water column pressure (part of automated air bleed) see
Table 31; for the onboard tank water level sensor (or Foam Tank A/Foam Tank B), refer to the
Class 1 Operation Manual, Intelli-Tank Level 40 (P/N 118253).
Table 29. Hale Discharge Valve Pressure Sensor Wiring (From/To Listing)
From Pressure Transducer Pin
To Valve Driver Pressure Connector Pin
A (Ground)
3
Ground
[Output]
B (Power)
4
Power
[Output]
C (Pressure Signal)
1
Pressure Signal
[Input]
Summary of Contents for Hale Sam
Page 2: ......
Page 37: ...17 Figure 14 SAM Blue CAN Buss Architecture With Three SAM Control Centers Diagram...
Page 38: ...18 Figure 15 SAM Green CAN Buss Architecture With Three SAM Control Centers Diagram...
Page 39: ...19 Figure 16 SAM Red CAN Buss Architecture With Three SAM Control Centers Diagram...
Page 40: ...20 Figure 17 SAM System Drain And Pneumatic Diagram...
Page 41: ...21 Figure 18 SAM Speaks Diagram...
Page 42: ......
Page 58: ...38 THIS PAGE INTENTIONALLY BLANK...
Page 62: ...42 THIS PAGE INTENTIONALLY BLANK...
Page 192: ...172 THIS PAGE INTENTIONALLY BLANK...
Page 206: ...186 THIS PAGE INTENTIONALLY BLANK...
Page 220: ...200 THIS PAGE INTENTIONALLY BLANK...