68
H.
When SELECT DEVICE MENU appears, touch desired valves row in list.
I.
When EDIT VALVE screen appears, note/record all parameters listed. (Friendly
Name, Index, Function, MAX PSI, Preset PSI, Preset CAFS, CAFS Capable, Diame-
ter, and Color[s]) (Up to three.)
NOTES
Refer to FSG-PL-01508, enter VALVE P/N based on table located in the drawing; enter
VALVE MOTOR POSITION based on comparing physical valve to POSITION 1 thru POSI-
TION 4 located in drawing; enter NAME ON CONTROL SCREEN based on Friendly Name
from Step I (above); SCREEN LOCATION (enter D1 thru D12) based on the D number
references shown on the MANUAL VALVE CONTROL screen in the drawing); enter
COLOR based on Color(s) from Step I (above); and WATER ONLY/FOAM/CAFS based
on Preset CAFS, CAFS Capable parameters from Step I (above).
The recorded parameters will be entered after the replacement valve is installed and
ONLY if the valve requires configuration. (See section 6, SAM Setup/Configuration,
page 187.)
J.
Exit EDIT VALVE screen. (Touch Home icon; top center of screen.)
K.
Reboot to GUI as follows.
Touch MENU button (top center of screen).
When Home MENU screen appears, touch More button.
Touch Reboot to GUI button.
4.5.2
Discharge And Special Purpose Valve Removal And Replacement
Prior to removing an Akron Brass valve, perform paragraph 4.5.1 (above). If the valve requires
clocking (for physical override access purposes), perform paragraph 4.5.3, (below) to ensure the
valve physically operates correctly after reassembly.
AKRON BRASS SWING-OUT
TM
VALVES FROM A DISCHARGE PORT WILL NOT FUNCTION
IN THE PLACE OF ANY SPECIAL PURPOSE VALVE (TF, T2P, PONY) IN A HALE SAM SYS-
TEM. DO NOT USE ONE FOR SUBSTITUTION OR REPLACEMENT PURPOSES.
Tank Fill Valve
The tank fill supports water supply management (intake) even though it connects to a pump dis-
charge port (it is used to replenish the water supply provided by the onboard water tank).
Typically, a 2-in Style 8600 Swing-Out™ valve with electric actuator and motor driver is con-
nected to port I or port B for a Qmax-XS or port B for a Qmax to provide tank fill water flow.
For Akron Brass valve address information, see paragraph 2.4.5 (page 26) and for valve
size/part number reference the SAM Parts Manual (FSG-MNL-00212). Also reference the SAM
PM for the Qmax-XS (refer to FSG-PL-01209) and Qmax (refer to FSG-PL-01510) port diagram lo-
cated on the flash drive provided with the pump or available from the Hale Products website
(www.haleproducts.com).
Tank-To-Pump Valve
Typically, a 3-in Style 8600 Swing-Out™ valve with electric actuator and motor driver is con-
nected to port S for a Qmax-XS or Qmax to provide tank-to-pump water flow. For Akron Brass
valve address information, see paragraph 2.4.5 (page 26) and for valve size/part numbers refer-
ence the SAM Parts Manual (FSG-MNL-00212). Also reference the SAM PM for the Qmax-XS
Summary of Contents for Hale Sam
Page 2: ......
Page 37: ...17 Figure 14 SAM Blue CAN Buss Architecture With Three SAM Control Centers Diagram...
Page 38: ...18 Figure 15 SAM Green CAN Buss Architecture With Three SAM Control Centers Diagram...
Page 39: ...19 Figure 16 SAM Red CAN Buss Architecture With Three SAM Control Centers Diagram...
Page 40: ...20 Figure 17 SAM System Drain And Pneumatic Diagram...
Page 41: ...21 Figure 18 SAM Speaks Diagram...
Page 42: ......
Page 58: ...38 THIS PAGE INTENTIONALLY BLANK...
Page 62: ...42 THIS PAGE INTENTIONALLY BLANK...
Page 192: ...172 THIS PAGE INTENTIONALLY BLANK...
Page 206: ...186 THIS PAGE INTENTIONALLY BLANK...
Page 220: ...200 THIS PAGE INTENTIONALLY BLANK...