173
5.
ADJUSTMENTS
All significant calibrations for the SAM system can be perform from the SAM Control Center or the
SAM Pump Controller. The SAM Control Center can perform any Akron Valve calibration required,
while the SAM Pump Controller can calibrate the ITL-40 sensor and perform Governor calibra-
tions.
5.1.
Akron Valve Firmware Information (S/N and USB Update)
Using an Akron Brass Swing-Out™ valve with a Navigator Pro (or Akroview) requires knowing the
valves serial number. Figure 140 shows an example of the serial number markings.
Figure 140. Akron Valve Serial Number
5.2.
Akron Brass Swing-Out™ Valve Calibrations
DISENGAGE PUMP BEFORE PERFORMING CALIBRATION, OTHERWISE UNEXPECTED/
UNDESIRABLE AUTOMATED OPERATIONS MAY OCCUR DURING CALIBRATION.
REMOVE SYSTEM PRESSURE BEFORE PERFORMING CALIBRATION. OPEN ALL DRAINS
AND AIR BLEED VALVES TO ENSURE THE SYSTEM IS NOT PRESSURIZED AND THE
VALVE(S) CAN BE OPENED AND CLOSED SAFELY BEFORE PROCEEDING WITH VALVE
CALIBRATION.
Reference paragraph 8.1.2.3, Akron Valve Firmware Information (S/N and USB update), when
calibrating an AB Swing-Out™ valve with a Navigator Pro (or Akroview) as this process requires
knowing the valves serial number. Reference Figure 118 for an example of the serial number
markings.
Reference section 8.1, Calibration Of AB Swing-Out™ Valves, in the OIM Manual For Hale SAM
(Generation 2) (P/N FSG-MNL-00210) to calibrate the SAM electric valves.
5.2.1
Valve Position Procedures (SAM Control Center)
Three separate calibrations are available from the SAM System Options, Calibration tab, CALI-
BRATION MENU screen (Figure 141): Valve Stops, Calibrate Pressure Sensors, or Flowmeter Cali-
bration. Each of the calibrations must be run for every Akron Brass Swing-Out™ valve on the Red
(discharge valves) and GREEN (auxiliary intake valves, tank fill, and tank-to-pump valves CAN)
bus.
Summary of Contents for Hale Sam
Page 2: ......
Page 37: ...17 Figure 14 SAM Blue CAN Buss Architecture With Three SAM Control Centers Diagram...
Page 38: ...18 Figure 15 SAM Green CAN Buss Architecture With Three SAM Control Centers Diagram...
Page 39: ...19 Figure 16 SAM Red CAN Buss Architecture With Three SAM Control Centers Diagram...
Page 40: ...20 Figure 17 SAM System Drain And Pneumatic Diagram...
Page 41: ...21 Figure 18 SAM Speaks Diagram...
Page 42: ......
Page 58: ...38 THIS PAGE INTENTIONALLY BLANK...
Page 62: ...42 THIS PAGE INTENTIONALLY BLANK...
Page 192: ...172 THIS PAGE INTENTIONALLY BLANK...
Page 206: ...186 THIS PAGE INTENTIONALLY BLANK...
Page 220: ...200 THIS PAGE INTENTIONALLY BLANK...