background image

Gast will NOT guarantee field-rebuilt product

performance. For performance guarantee, the product

must be returned to a Gast Authorized Service Facility.

Service Kit contents vary. Most contain gasket and filter

parts.

SERVICE KIT INSTALLATION

c

Disconnect electrical power supply cord before

installing Service Kit.
If product is hard wired into system, disconnect

electrical power at the circuit breaker or fuse box

before installing Service Kit.
Vent all air lines to release pressure or vacuum.
Failure to follow these instructions can result in

death, fire or electrical shock.

WARNING

Electrical Shock Hazard

7. Clean head and valve plate using water-based

solvents.

8. Reattach exhaust valve and valve retainer to valve

plate. Note location of “X” stamped on valve retainer.

This must be orientated as shown or valve may break

prematurely.

9. Torque pan head screw to 12 in.-lbs. (once assembled,

make sure valve remains over exhaust port when

closed).

10. Reinstall gasket and valve plate into head. Valve plate

and head are designed so that valve plate can be

installed in one orientation only.

11. Install four flat head screws and torque to 12 in-lbs.

12. Reinstall intake valve and its retainer. Note location of

“X” stamped on valve retainer. This must be orientated

as shown or valve may break prematurely.

13. Reinstall pan head screw and torque to 12 in-lbs.

14. Tighten head in place using four head screws and

torque to 25-27 in-lbs.

Check that all external accessories such as relief valves

and gauges are not damaged before

re-operating product.

If pump still does not produce proper vacuum or pressure,

send unit to a Gast Authorized Service Facility for repair.

Follow these steps to replace diaphragm:

1. Label ports noting direction of arrows so you can orient

pump head correctly during reinstallation.

2. Remove four corner head screws.

3. Remove head assembly.

NOTE:Head assembly is inseparable. Do not attempt to

disassemble.

4. Remove four flat head screws on retainer plate.

5. Remove retainer plate and diaphragm.

6. Clean pump head and retainer using water base solvents.

NOTE:

Do not use petroleum-base compounds, acids, caustics,
or chlorinated solvents to clean or lubricate any parts, It
will reduce service life of pump.

7. Re-attach retainer plate and diaphragm to rod with four flat

head screws. Torque screw to 20 in-lbs.

8. Make certain diaphragm is in recessed area of bracket and

re-install head assembly in proper orientation, twisting it

slightly back and forth to seat diaphragm in head and bracket.

9. Tighten head in place using four head screws and torque to

25-27 in-lbs.

Valve Replacement
Follow these steps to replace valves:

1. Label ports noting direction of arrows so you can orient

pump head correctly during reinstallation.

2. Remove four corner head screws.

3. Remove head assembly.

4. Remove valve plate by removing four flathead screws

around perimeter and pan head screw in center (this screw

also retains intake valve).

5. Remove intake valve, its retainer, valve plate and gasket.

6. Remove pan head screw from other side of valve plate (this

screw retains exhaust valve).

Summary of Contents for GAST 22D Series

Page 1: ...Distributor Representative before using at high altitudes This pump is oil less and requires NO lubrication Thank you for purchasing this Gast product It is manufactured to the highest standards usin...

Page 2: ...able rigid operating surface and using shock mounts will reduce noise and vibration Accessories Install gauges in the lines to monitor performance A relief valve can be installed at the inlet or outle...

Page 3: ...onform to all required safety codes and be installed by a qualified person Check that supply voltage agrees with that listed on product nameplate Extension cords Use only a 3 wire extension cord that...

Page 4: ...cal shock Electrical Shock Hazard WARNING Injury Hazard Product surfaces become very hot during operation allow product surfaces to cool before handling Air stream from product may contain solid or li...

Page 5: ...all external accessories such as relief valves and gauges are not damaged before re operating product If pump still does not produce proper vacuum or pressure send unit to a Gast Authorized Service Fa...

Page 6: ...NTIAL DAMAGES OF ANY KIND however arising including but not limited to those for use of any products loss of time inconvenience lost profit labor charges or other incidental or consequential damages w...

Page 7: ...g or ordering parts please give complete model and serial numbers REF DESCRIPTION QTY 22D 1 HEAD SCREWS 4 SCR1001 2 HEAD 1 HDC1003 3 HEAD GASKET 1 ACC1018 4 INTAKE VALVE SCREW 1 SCR1017 5 RETAINER VAL...

Page 8: ...otor not wired correctly Check wiring diagram line voltage Blown head gasket Replace TROUBLESHOOTING CHART www gastmfg com ISO 9001 14001 CERTIFIED For repair parts ordering information and exploded p...

Reviews: