background image

Low

High

Pump

Won’t

Excess

Reason and remedy

Vacuum

Pressure

Vacuum

Pressure

Overheat

Start

Noise

for problem.

Filter dirty. Clean or replace.

Muffler dirty. Clean or replace.

Valves dirty or valves bent.

Clean or replace.

Worn cup.

Repair or replace.

Relief valve set too high.

Inspect and adjust.

Relief valve set too low.

Inspect and adjust.

Plugged vacuum/pressure line.

Inspect and repair.

Collapsed vacuum line.

Inspect and repair.

Low voltage, wonʼt start.

Check power source.

Voltage wrong.

Check power source.

Worn cup/piston hitting cylinder.

Replace.

Cylinder misadjustment.

Realign.

Leaky hose or check valve.

Replace.

Dirt or liquid on top of piston.

Inspect and clean.

Motor not wired correctly.

Check wiring diagram/line voltage.

Blown head gasket.

Replace.

TROUBLESHOOTING CHART

www.gastmfg.com

ISO 9001 & 14001 CERTIFIED

For repair parts ordering information and exploded product view, visit our website or
call us at the number listed below.

We have Gast Authorized Repair Facilities throughout the world. For the most up-to-

PART NO. 70 - 6900 G497PL (REV-H)

Gast Manufacturing, Inc.

2300 S. Highway M139

Benton Harbor, MI,49022

Ph: 269/926-6171

FAX: 269/925-8288

www.gastmfg.com

Gast Hong Kong

Unit 12, 21/F, Block B

New Trade Plaza

6, On Ping Street, Shatin

N. T. Hong Kong

Ph: (852) 2690 1066

Fax: (852) 2690 1012

www.gasthk.com

European Sales & Service

Headquarters

Gast Group Limited

A Unit of IDEX Corporation

Unit 11, The I O Centre

Nash Road

Redditch B98 7AS

United Kingdom

Tel: +44 (0) 1527 504040

Fax: +44 (0) 1527 525262

www.gastmfg.com

www.jun-air.com

Summary of Contents for GAST 22D Series

Page 1: ...Distributor Representative before using at high altitudes This pump is oil less and requires NO lubrication Thank you for purchasing this Gast product It is manufactured to the highest standards usin...

Page 2: ...able rigid operating surface and using shock mounts will reduce noise and vibration Accessories Install gauges in the lines to monitor performance A relief valve can be installed at the inlet or outle...

Page 3: ...onform to all required safety codes and be installed by a qualified person Check that supply voltage agrees with that listed on product nameplate Extension cords Use only a 3 wire extension cord that...

Page 4: ...cal shock Electrical Shock Hazard WARNING Injury Hazard Product surfaces become very hot during operation allow product surfaces to cool before handling Air stream from product may contain solid or li...

Page 5: ...all external accessories such as relief valves and gauges are not damaged before re operating product If pump still does not produce proper vacuum or pressure send unit to a Gast Authorized Service Fa...

Page 6: ...NTIAL DAMAGES OF ANY KIND however arising including but not limited to those for use of any products loss of time inconvenience lost profit labor charges or other incidental or consequential damages w...

Page 7: ...g or ordering parts please give complete model and serial numbers REF DESCRIPTION QTY 22D 1 HEAD SCREWS 4 SCR1001 2 HEAD 1 HDC1003 3 HEAD GASKET 1 ACC1018 4 INTAKE VALVE SCREW 1 SCR1017 5 RETAINER VAL...

Page 8: ...otor not wired correctly Check wiring diagram line voltage Blown head gasket Replace TROUBLESHOOTING CHART www gastmfg com ISO 9001 14001 CERTIFIED For repair parts ordering information and exploded p...

Reviews: