6.3.4.13:
CNTLESS_SET_CONFIG_PARAMS
This Escape command is used to configure RXGAIN and RXTHRESHOLD of the RF receiver for different
baud rates and card types. All configured parameters are volatile.
Input:
The first byte of the input buffer contains the escape code. The following 16 bytes contain these
parameters:
Byte # Value
Description
B0
0xE1
Escape code
B1
Type A RXGAIN for polling or 106 Kbps
B2
Type A RXGAIN for 212 Kbps
B3
Type A RXGAIN for 424 Kbps
B4
Type A RXGAIN for 848 Kbps
B5
Type A RX THRESHOLD for polling or 106 Kbps
B6
Type A RX THRESHOLD for 212 Kbps
B7
Type A RX THRESHOLD for 424 Kbps
B8
Type A RX THRESHOLD for 848 Kbps
B9
Type B RXGAIN for polling or 106 Kbps
B10
Type B RXGAIN for 212 Kbps
B11
Type B RXGAIN for 424 Kbps
B12
Type B RXGAIN for 848 Kbps
B13
Type B RX THRESHOLD for polling or 106 Kbps
B14
Type B RX THRESHOLD for 212 Kbps
B15
Type B RX THRESHOLD for 424 Kbps
B16
Type B RX THRESHOLD for 848 Kbps
Output:
Output buffer
NULL