9. TECHNICAL DATA
Communication Broadcast 350
Operation Mode
Transmits Sensor ID and user data in pre-defined interval
Read Range
up to 500m*
Compatibility
i-PORT M350, i-CARD CF 350 and i-PORT 4-350
Operating Frequency
868 MHz (EU) or 920 MHz (NA)
Transmit Power
<1mW
Communication Response 350
Operation Mode
Bi-directional communication (reading log, blink LED, write/read
data)
Read Range
up to 250m*
Compatibility
i-PORT M350 and i-CARD CF 350
Operating Frequency
868 MHz (EU) or 920 MHz (NA)
Transmit Power
<1mW
Data
Data Retention
> 10 years without power
Write Cycles
100,000 writes
Memory Size
10,000 Bytes user definable
Identification Code
48 bit fixed ID
Configuration
Device
i-PORT M350 or i-CARD CF350
Ping Rate
Configurable from 0.5 to 300 seconds insteps of 0.5 seconds
Number of Bursts
Configurable from 0 to 15
Broadcast User Data
Up to 50 Bytes
Interface
serial interface
RS232 Deutsch connector
supported Reefer units
Thermo King
MP4000 (monitoring only)
Daikin
Decos IIIc
Decos IIId
Starcool
RCCU5
SCC6
Carrier
Microlink 3
Microlink 2i
Microlink 2
Electrical
Power Source
Lithium Battery (replaceable)
Battery Monitoring
Yes