background image

 

i-B350L -CC 

– Hardware User Manual | 20. September 2019 

 

Copyright © 2019 IDENTEC SOLUTIONS. All rights reserved. 

2

 

 
Proprietary Notice 

This document contains confidential information proprietary to IDENTEC SOLUTIONS and may not be used or 
disclosed to other parties in whole or in part without the prior written authorization from IDENTEC SOLUTIONS. 

 

Disclaimer and Limitation of Liability 

IDENTEC SOLUTIONS AG and its affiliates, subsidiaries, officers, directors, employees and agents do not make 
any express or implied warranties or representations with respect to such information including, without limitation, 
warranties as to non-infringement, reliability, suitability for a particular purpose and accuracy. IDENTEC 
SOLUTIONS shall not under any circumstances be liable to any person for any special, incidental, indirect or 
consequential damages, including without limitation, damages resulting from use of or reliance on information 
presented herein, or loss of profits or revenues or costs of replacement goods, even if informed in advance of the 
possibility of such damages. 

 

Trademarks 

“IDENTEC SOLUTIONS”, “Intelligent Long Range”, “ILR” and the stylized “i” are registered trademarks.  
“i-PORT” and “Visibility Delivered.” are trademarks of IDENTEC SOLUTIONS, Inc. and/or IDENTEC SOLUTIONS 
AG. 

 

Copyright Notice 

Copyright © 2019 IDENTEC SOLUTIONS. All rights reserved. 

No part of this document may be reproduced or transmitted in any form by any means, photographic, electronic, 
mechanical or otherwise, or used in any information storage and retrieval system, without the prior written 
permission of IDENTEC SOLUTIONS. 

 

 

Issue 3.0 / September 2019 (MOM) 

 

Subject to alteration without prior notice. 

Copyright © 2019 IDENTEC SOLUTIONS AG 

Printed in Austria

 

 

Summary of Contents for i-B350L-CC

Page 1: ...IDENTEC SOLUTIONS i B350L CC HARDWARE USER MANUAL...

Page 2: ...able to any person for any special incidental indirect or consequential damages including without limitation damages resulting from use of or reliance on information presented herein or loss of profit...

Page 3: ...and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a resid...

Page 4: ...hing screw on the unit Best practice is to use an antistatic ribbon and earth yourself permanently for the time you handle the unit Avoid unnecessary contact with the unit connectors and assemblies in...

Page 5: ...slowly adjust itself to warmer temperatures after removal from cold and cool environments Connections Power Supply The supply circuits must comply with the conditions set out for the SELV circuits se...

Page 6: ...8 2 2 System Components Tags 8 2 3 System Components Readers 9 2 4 System Components Antennas 10 3 Configuration of the Tag 11 3 1 General 11 3 2 Ping Rate 11 3 3 Bursts when passing a Position marke...

Page 7: ...e right to make changes and updates to the content contained herein It is the user s responsibility to contact the service department for any possible changes or updates to operating and maintenance p...

Page 8: ...i B350L CC tag can operate maintenance free up to eight years In combination with IDENTEC s i Mark RFID tag exciter the i B350L CC provides accurate localization for gates zones and lanes The credit c...

Page 9: ...eters i PORT BT USB The battery powered mobile reader with Bluetooth and USB interface communicates with a wide spectrum of handheld devices and tablet computers It is ideally suited for mobile applic...

Page 10: ...should be used Other antennas not provided by IDENTEC SOLUTIONS may void permit of use and violate compliance regulations Omnidirectional sub 1GHz Antenna Dimensions Half wave Dipole Antenna Ordering...

Page 11: ...dependent from regular Pings Marker technology Bursts triggered by the push button can be configured independent from regular Pings Tools Needed PC running on MS Windows with the SensorSMART Tool soft...

Page 12: ...er determines the contents of the burst messages 3 4 Limitations of the User Data Field The total length of the broadcast message burst or ping is limited to 50 Bytes So depending on the broadcast mes...

Page 13: ...i B350L CC Hardware User Manual 20 September 2019 Copyright 2019 IDENTEC SOLUTIONS All rights reserved 13 The last row shows how the random use of the timeslot avoids collision between the tags...

Page 14: ...er A Brief Checklist Are all housings intact Are all cables intact Are all connectors intact Are all connectors securely fastened Are all screws still tight Is there a sudden malfunction at a specific...

Page 15: ...rable from 0 to 15 Broadcast User Data Up to 50 Bytes Electrical Power Source Lithium Battery non replaceable Battery Monitoring Yes Environmental Conditions Operating Temperature 30 C to 70 C 22 F to...

Page 16: ......

Reviews: