Wiegand Communication
293732943-F
14
Step
three
:
c
omm
unic
at
ion
s
Wiegand Out
Wiegand In
LED Out
Wiegand IN & Wiegand OUT
22
WIEGAND_IN0
Green / Red
23
WIEGAND_IN1
White / Red
20
WIEGAND_GND
Black / Red
24
WIEGAND_OUT0
Green
21
WIEGAND_OUT1
White
25
WIEGAND_LEDOUT1 Blue
26
WIEGAND_LEDOUT2 Blue / Red
GP IN & OUT
10
GPO0
Yellow
LED In
Three-conductor wire (shielded recommended) is required for Data 0, Data 1, and WGND.
Use 18-22 AWG cable in a homerun configuration from each unit to the Access Control Panel (ACP).
Connect WIEGAND_OUT0 (Green Wire) to ACP Data 0,
Connect WIEGAND_OUT1 (White Wire) to ACP Data 1,
Connect WIEGAND_GND (Black / Red Wire) to ACP reader common (0vDC).
For 18 AWG, the maximum cable distance is 500 ft. (150m); for 20 AWG, the maximum is 300 ft. (90m); for 22
AWG, the maximum is 200 ft. (60m).
Electrical interface conforms to the Security Industry Association's Wiegand standard March 1995, and it is 5V
TTL compatible.