2
POWER SUPPLY
DESCRIPTION
MODEL
DOM-12 / DOM-12 PH /
DOM-12 PLUS
DOM-24 / DOM-24 PH /
DOM-24 PLUS
DOM-32 / DOM-32 PH /
DOM-32 PLUS
DOM-42 / DOM-42 PH /
DOM-42 PLUS
Standard working voltage
230 V AC, 50/60 Hz.
Output (dc)
12 A (2x6 A)
24 A (2x12 A)
32 A (2x16A)
42 A (6x7A)
Production (g/h)
10 - 12
20 -24
25 - 32
34 - 42
Swimming pool (m
3
)
Warm: 16 – 24°C (60,8 – 75,2 °F)
Hot: +25°C (77 °F)
60
50
100
80
160
120
200
160
Flow detector
Gas detector
Salinity /Temperature range
3 – 12 g./l. / +15 - 40
o
C (59 – 104
o
F)
Electrodes
SELF-CLEANING coated Titanium
Estimated lifetime: 4.000 – 7.000 hours of operation
Production control
0 – 100 % ( 11 production levels)
Cover control
Input for potential free contact
Programmable reduction of production from control panel when cover is closed [10% ... 90%]
Polarity switch
Programmable from control panel: 2/3 hours + test mode
External control
Two inputs for potential free contact for external flow detector and ORP/RESIDUAL CHLORINE control.
Programmable contact logics from unit control panel
Salt level protection
Automatic production protection
ELECTROLYSIS CELL
DESCRIPTION
MODEL
DOM-12 / DOM-12 PH /
DOM-12 PLUS
DOM-24 / DOM-24 PH /
DOM-24 PLUS
DOM-32 / DOM-32 PH /
DOM-32 PLUS
DOM-42 / DOM-42 PH /
DOM-42 PLUS
Minimum recirculation flow
2 m
3
/h 4
m
3
/h
6 m
3
/h 8
m
3
/h
Electrode number
5
7
7
13
Material Methacrylate
derivate
Pipe connections
Gluing with PVC adhesive Ø 63 mm
Max. Recommended pressure
1 Kg./cm
2
Working temperature
Less than 40
o
C (104°F)
PH / ORP CONTROL
DESCRIPTION
MODEL
DOM-12 PH
DOM-12 PLUS
DOM-24 PH
DOM-24 PLUS
DOM-32 PH
DOM-32 PLUS
DOM-42 PH
DOM-42 PLUS
Measure range
0.0 – 9.9 (pH) / 0 – 999 mV (ORP)
Control range
7.0 – 7.8 (pH) / 600 - 850 mV (ORP)
Precision
± 0.1 pH / ± 1 mV
Calibration
Automatic, with calibration solutions
Control output [pH]
One output 230 VAC / 500 mA for dosage pump connection
pH / ORP sensor
Epoxy body, 12x150 mm., 0-80
o
C (32 – 176°F)
blue, range 0 – 12 (pH),
red, range 0 – 1000 mV (ORP)
Summary of Contents for DOM-12 PH
Page 1: ......
Page 4: ...3 Fig 1 Recommended installation diagram DOMOTIC Series DOM XX...
Page 5: ...4 Fig 2 Recommended installation diagram DOMOTIC Series DOM XX PH and DOM XX PLUS...
Page 10: ...9...
Page 16: ...15 Fig 23 System programming flow sheet...
Page 30: ...29 Dimensions DOMOTIC DOM XX models DOMOTIC PH PLUS DOM XX PH and DOM XX PLUS models...