19
Fig. 27d.
5.6.
Alarms
HIGH SALT LEVEL
If too much salt has been added, the production level will automatically fall beneath the selected level. The “HIGH SALT” [7] light
will stay on. In this case, empty part of the pool (10%, for instance) and add fresh water to reduce the salt concentration. To
precisely measure the salt level, we recommend the use of a portable salinity-temperature meter
LOW SALT LEVEL
If there is less than the recommended salt content in the pool, the selected output level cannot be reached. The “LOW SALT” [6]
light will stay on. In this case, measure the salt level in the water and add the required amount of salt. The common salt (NaCl)
used for electrolysis should not contain additives (anti-caking agents, iodine) and must be suitable for human consumption. The
system may indicate a low salt level if the temperature falls beneath 20°C (68 °F). To precisely measure the salt level, we
recommend the use of a portable salinity-temperature meter.
High salt level
Low salt level
Fig. 28