7.

 

TROUBLESHOOTING: ________________________________________________________________________________________   

 
Any action required to solve possible problems in the equipment should always be performed with the equipment disconnected from the 
mains.  Any problem not indicated in the following list should be solved by an IDEGIS technician. 
 

PROBLEM 

 

SOLUTION 

 

Production indicator always indicates  “0” at all production levels 

Check electrodes. 

Verify connections between power supply and the electrolysis 
cell. 

Check salt concentration. 

 

The power supply is not turned on. 

 

Check the system is properly connected to 230 V/50-60 Hz in the 
command box of the pump. 

Check th estate of teh fuse located at the bottom of the power 
supply. 

 

Free chlorine levels in the water are very low. 

Check that the system produces chlorine in pool jets. 

Verify that the water Chemicals parameters (pH, combined 
chlorine, isocyanuric acid, etc.) are correct. 

Increase filtering time. 

Add chlorine stabilizer (cyanuric acid) until a concentration of 25 – 
30 g/m

3

 is achieved. 

 

pH/ORP controller always show extreme values, or readings are 
unstable. 

The cable of the pH/ORP sensor is damaged. Clean the contacts 
or replace the cable. 

The pH/ORP sensor has an air bubble in the membrane area. 
Hold the sensor in vertical position.Shake it lightly until the bubble 
moves up. 

Sensor fault. The connection cable is too long or it is too near to 
sources of electrical interference (motors, etc.). Replace the 
sensor. Locate the unit nearer to the sensor. 

 

Impossible calibration of the pH/ORP sensor 

Polluted or expired calibration solution. 

Blocked sensor membrane. Check the membrane is not 
damaged. Clean the sensor with diluted acid in water, shaking it 

lightly. 

Sensor fault. Replace the sensor. 

 

Slow response of the pH/ORP sensor 

Sensor electrostatically charged. During the calibration phase, the 
sensors should not be dried with paper or cloth. Clean it exclusively 
with water and shake it lightly. 

Insufficient renovation of the analyzed water (no flow through the 
sample point). Ensure that the tip of the sensor is submerged in the 
water at the sample point, and that no air bubbles are present. 

 

 

Summary of Contents for DOM-12 PH

Page 1: ......

Page 2: ...This salty water then passes through the electrolysis cell that is located in the plant room The DOMOTIC Series Salt Electrolysis System consists of two elements an electrolysis cell and a power supp...

Page 3: ...potential free contact for external flow detector and ORP RESIDUAL CHLORINE control Programmable contact logics from unit control panel Salt level protection Automatic production protection ELECTROLY...

Page 4: ...3 Fig 1 Recommended installation diagram DOMOTIC Series DOM XX...

Page 5: ...4 Fig 2 Recommended installation diagram DOMOTIC Series DOM XX PH and DOM XX PLUS...

Page 6: ...of the cell should allow easy access to the installed electrodes by the user It is highly recommended to install the electrolysis cell VERTICALLY in a place of the pipe that can be easily isolated fro...

Page 7: ...en the electrolysis cell and the power supply according to the following scheme Due to relatively high current intensity circulating do not modify or cut either the length or section of the supplied c...

Page 8: ...13 Fig 12 Fig 13 4 5 Installation of the optional external flow detector not included with the equipment 1 Install the saddle supplied in a section of the pipe at the entrance to the electrolysis cell...

Page 9: ...Fig 11 1 and sliding upwards and outwards Fig 11 2 Then turn the cover to the left Fig 11 3 and disconnect the communications bus A from power and visualization cards Fig 11 4 2 Unscrewing its four f...

Page 10: ...9...

Page 11: ...10 4 8 Controls and indicators DOMOTIC Series electrolysis systems are equipped with a control panel in the front Figs 15 16 16b Fig 15 DOM XX models control panel Fig 16 DOMXX PH models control panel...

Page 12: ...tors DIRECT REVERSE polarity 11 Display of SYSTEM INFORMATION 12 Indicator of FLOW ALARM 13 Indicator of ELECTRODE passivation ALARM 14 Key increase production programming menu navigation 15 Display o...

Page 13: ...ent input for potential free contact When the contact connected to this input is open external flow detector at rest and the FS is configured as FS1c the electrolysis system switches off due to the fl...

Page 14: ...the minimum recommended level of salt 5 g l should be maintained by adding 5 kg per m 3 of water if the water did not previously contain salt Always use common salt sodium chloride without additives l...

Page 15: ...s you to establish the following operative parameters MODEL domotic 12 domotic 24 domotic 32 domotic 42 SOFTWARE VERSION Shows software version two digits POLARITY SWITCH Switch every 2 hours 2 Switch...

Page 16: ...15 Fig 23 System programming flow sheet...

Page 17: ...tion value 4 could be lower than the programmed and displayed value 11 WINTER Mode during periods of low water temperature select a production level 1 in the 50 60 range 5 4 Salinity test The DOMOTIC...

Page 18: ...OF THE PH ORP SENSORS models DOM XX PH and DOM XX PLUS Connect the pH ORP sensor provided with the unit to the corresponding BNC connectors located in the unit s base Fig 26 5 5 2 CONNECTION OF THE D...

Page 19: ...the dosage pump which allows to avoid the following situations Damages caused by the dry operation of pump depleted pH minus product Over dosage of pH minus product damaged or aged sensor PH regulati...

Page 20: ...VEL If there is less than the recommended salt content in the pool the selected output level cannot be reached The LOW SALT 6 light will stay on In this case measure the salt level in the water and ad...

Page 21: ...System running 2 Gas detected Insufficient flow System off Fig 29 OPTIONAL EXTERNAL FLOW DETECTOR FLOW SWITCH not included with the equipment During the system configuration process point 5 2 the inpu...

Page 22: ...due to excessive scaling on the electrodes when the system operates with hard water with a high pH value Fig 31 PH ORP OUT OF RANGE only in models DOM XX PH and DOM XX PLUS The integrated pH ORP contr...

Page 23: ...Although all DOMOTIC series salt electrolysis units are SELF CLEANING a prolonged operation of the system at pH values over 7 6 in waters of high hardness can produce scale formation on the surface of...

Page 24: ...until the pH screen 15 displays a blinking 7 0 3 Gently shake the sensor to remove any possible drops of water and insert in the standard pH 7 0 solution green Gently shake for a few seconds and pres...

Page 25: ...ntroller will be determined in each particular application Nevertheless we recommend to make it at least once a month during the use period of the pool The ORP controller has an automatic calibration...

Page 26: ...lay 21 will indicate E2 not allowing calibration If the ORP measure is unstable during the calibration process code E3 will appear in display 21 In addition the sensor calibration will not be allowed...

Page 27: ...zer cyanuric acid until a concentration of 25 30 g m 3 is achieved pH ORP controller always show extreme values or readings are unstable The cable of the pH ORP sensor is damaged Clean the contacts or...

Page 28: ...pump Electrolysis display card Electrolysis pH display card Electrolysis PH ORP display card Power transformer 190 VA Power transformer 370 VA Power transformer 480 VA Power transformer 490 VA Extern...

Page 29: ...42 8 m3 h Electrode number Domotic Series 12 5 Domotic Series 24 7 Domotic Series 32 7 Domotic Series 42 13 Net weight packaging included Domotic Series 12 11 Kg Domotic Series 24 13 Kg Domotic Series...

Page 30: ...29 Dimensions DOMOTIC DOM XX models DOMOTIC PH PLUS DOM XX PH and DOM XX PLUS models...

Page 31: ...ve the buyer must closely follow the manufacturer s instructions included in the documentation supplied with the product as applicable to each product range and model 10 2 2 Whenever a schedule is def...

Page 32: ...cambiare totalemente o parzialmente le caratteristiche technique dei nostri prodotti ed il cotenuto di questo docuemntosenza nessum preavviso Wir behalten uns das recht vor die eigenschatten unserer p...

Reviews: