IDEC SE9Z-HC Instruction Manual Download Page 6

5

 

Fixed blanking function, floating blanking function

 

● With the fixed blanking function, this device prevents the person or object from entering into 

the dangerous parts of the machine through the invalid sensing area. However, even though 

this device can prevent the interference of the person or object into the invalid sensing area 

with the fixed blanking function, there might exist the more space between the 

SE4D

 series 

and already-existence object. Therefore, set the protecting structure so as not to exist any 

space in the dangerous sensing area. Detecting human body in the sensing area could result 

in death or serious injury.

 

● With the floating blanking function, this device changes the size of the minimum sensing 

object of the 

SE4D

  series that is pre-set the function. When setting or changing the 

function, calculate and measure the safety distance again, and check that the device has the 

wider space than the safety distance between the dangerous parts of the machine and the 

sensing area of the 

SE4D

 series. If the sufficient distance is not maintained, the machine will 

not stop before its dangerous parts are reached, which can result in death or serious injury.

 

● Set and change the function of the device following the relative laws, regulation, and 

standard without fail.

 

Muting setting changing function

 

● The muting setting changing function temporarily invalidates safety function of the connected 

devices. Confirm all of the applied laws and standards, and install or operate this device and 

peripheral devices correctly. Failure to do so, the operator may suffer a serious injury.

 

Environment

 

● Do not use a mobile phone or a radio phone near this device.

 

● Do not use this device in the following environments.

1) Areas with high humidity where condensation is likely to occur

2) Areas exposed to corrosive or explosive gases

3) Areas exposed to vibration or shock of levels higher than that specified

4) Areas exposed to contact with water

5) Areas exposed to too much steam or dust

 

Wiring

 

● Be sure to carry out the wiring in the power supply OFF condition.

 

● All electrical wiring should conform to the regional electrical regulations and laws. The wiring 

should be done by engineer(s) having the special electrical knowledge.

 

● Do not run the wires together with high-voltage lines or power lines or put them in the same 

raceway. This can cause malfunction due to induction.

 

Maintenance

 

● Clean this device with a clean cloth. Do not use any volatile chemicals.

 

Other

 

● Never reassemble or remodel this device.

INTRODUCTION

Summary of Contents for SE9Z-HC

Page 1: ...FUNCTION CANCEL ENTER INSTRUCTION MANUAL Handy Controller Exclusive for SE4D Series SE9Z HC B 1430 0 MJE SE9ZHC No 0027 96V ...

Page 2: ...1 MEMO ...

Page 3: ...device 1 All the contents of this instruction manual are the copyright of the publishers and may not be reproduced even extracts in any form by any electronic or mechanical means including photocopying recording or information storage and retrieval without permission in writing from the publisher 2 The contents of this instruction manual may be changed without prior notice for further improvement ...

Page 4: ...tive Function 13 3 1 10 Initialization Function 13 3 1 11 Setting Contents Monitoring Function 13 3 1 12 Override Setting Changing Function 13 3 2 Function Setting Operation Procedure 14 3 2 1 Fixed Blanking Function 17 3 2 2 Floating Blanking Function 18 3 2 3 Auxiliary Output Switching Function 19 3 2 4 Emission Intensity Control Function 20 3 2 5 Copy Function 21 3 2 6 Muting Setting Changing F...

Page 5: ... developed produced for industrial use only Before using this device check whether the device performs properly with the functions and capabilities as per the design specifications In case of disposal dispose this device as industrial waste User in charge The user in charge has responsible to indicate the person to take the training required for the safety system using method installation operatio...

Page 6: ...or serious injury Set and change the function of the device following the relative laws regulation and standard without fail Muting setting changing function The muting setting changing function temporarily invalidates safety function of the connected devices Confirm all of the applied laws and standards and install or operate this device and peripheral devices correctly Failure to do so the opera...

Page 7: ...nking function Floating blanking function Auxiliary output switching function Emission intensity control function Copy function Muting setting changing function Interlock setting changing function External device monitor setting changing function Protective function Initialization function Setting contents monitoring function Override setting changing function 2 2 Part Descriptions FUNCTION CANCEL...

Page 8: ...OSSD 1 2 of SE4D series is set to OFF while this device has been connected REFERENCE Refer to 3 1 Functional Descriptions for the details of the functions and refer to 3 2 Function Setting Operation Procedure for the setting procedures of the functions respectively 4 Turn OFF the power then remove this device 5 Check that the SE4D series works as set at the procedure 3 Then inspect the SE4D series...

Page 9: ...nking function respectively 3 1 Functional Descriptions When the fixed blanking function is used the control output OSSD 1 2 of SE4D series is not turned OFF even if the particular beam channels are blocked By using a protection structure etc make the dangerous parts of the machine inaccessible to personnel through the sensing area of the particular beam channels Before measures After measures Obs...

Page 10: ...s is turned ON Discontinuous mode CLR Ineffective When the beam channels are blocked discontinuously even in the set beam channels the control output OSSD 1 2 of SE4D series is turned OFF Continuous mode For use in Europe EU as EN 999 Also applicable to ISO 13855 For intrusion direction perpendicular to the sensing area In case that the minimum sensing object is ø40mm or less Equation S K T C S Sa...

Page 11: ...ng muting OFF ON during muting Others OFF OFF 7 OFF during muting ON OFF during muting Others ON ON 8 ON in light receiving condition Note 2 OFF ON OFF OFF 9 OFF in light receiving condition Note 2 ON OFF ON ON Notes 1 When the fixed blanking function the floating blanking function or the muting function is used the setting of ON OFF under unstable light receiving condition does not work 2 By the ...

Page 12: ... the functional setting data saved in this device This device SE4D series Copied SE4D series Copied SE4D series Original Upload Download Storage area for SE4D series 3 1 6 Muting Setting Changing Function The setting of the muting function can be changed Setting of the muting function on each beam channel Each beam channel can be set to effective ineffective in the muting function respectively Not...

Page 13: ...muting sensor which is to be connected to the muting input A ON with light non received status ON with object approaching status and ON with object contacted status A muting sensor which is to be connected to the muting input B ON with light received status ON with object non approaching status and ON with object non contacted status 3 1 7 Interlock Setting Changing Function One condition can be s...

Page 14: ...Note The setting of the protective function and the setting data of the copy function are not initialized 3 1 11 Setting Contents Monitoring Function Each setting of the SE4D series can be monitored The following can be monitored Model No the number of beam channels Setting of the fixed blanking function Reading out the record of the latest 5 times is possible Setting of the floating blanking func...

Page 15: ...iliary Output Switching Function To 3 2 4 Emission Intensity Control Function To 3 2 5 Copy Function To 3 2 6 Muting Setting Changing Function To 3 2 7 Interlock Setting Changing Function To 3 2 8 External Device Monitor Setting Changing Function To 3 2 9 Protective Function To 3 2 10 Initialization Function To 3 2 11 Setting Contents Monitoring Function To 3 2 12 Override Setting Changing Functio...

Page 16: ...ontents Monitoring Function is not locked 2 Once the password is input you do not need to input the password again till the power is turned OFF Except 3 2 9 Protective Function However if the power is turned ON again without changing the protective function to ineffective the password have to be input again since the protective function is still effective The procedure for inputting a password is ...

Page 17: ...s used CH2 CH3 cannot be selected When two SE4D series in series connection are used CH3 cannot be selected 3 2 3 Auxiliary Output Switching Function 3 2 7 Interlock Setting Changing Function or 3 2 8 External Device Monitor Setting Changing Function is set with CH1 only CH2 and CH3 are not indicated Function Setting When the units are not in series connection it is not indicated CH3 Sub sensor 2 ...

Page 18: ... OK It is possible to check ON OFF of all beam channels Input password OK NG Select send Error To 1 Send Input password Select beam channel Setting Manual setting OK NG Once a password is input it is not necessary to input it again till the power is turned OFF Beam channel No First beam channel Second beam channel Effective beam channel Ineffective beam channel The beam channel No is given with 1 ...

Page 19: ...channel mode CLR Ineffective Serial beam channel mode Note When all sensors is selected in the sensor selection the setting of the floating blanking function on each SE4D series should be identical Sub sensor 2 Sensor selection All sensors Main sensor Sub sensor 1 Set No of beam channel Ineffective Input password Send Error To 2 OK NG To 2 Send Error OK NG Ineffctive Effctive Ineffctive Note Effct...

Page 20: ...he received light level is unstable Note 1 Mode 6 ON during muting Mode 7 OFF during muting Mode 8 ON in the light receiving condition Mode 9 OFF in the light receiving condition Notes 1 This cannot be used when the fixed blanking function the floating blanking function or the muting setting changing function is used 2 When using with SE4D series only if the external device monitor function is not...

Page 21: ...els 0 3 to 7m for SE4D H 72 to 96 beam channels factory setting SET Effective The operating range is reduced by approx 50 Sub sensor 2 5 To Copy function Select sensor All sensors Main sensor Sub sensor 1 Emission intensity control Effective Ineffective Send Error To 4 OK NG Input pass word 4 Emission intensity con trol function key operation FUNCTION ENTER CANCEL ...

Page 22: ...tion setting 5 Copy function Select function Upload Download Monitor Select sensor Input password Check function 6 To Muting setting changing function Error To 5 OK NG Receive Error To 5 OK NG Receive Confirm function of system device Select item Note Note Note Note Detail display Only for SET Effective Ineffective Keep pressing switch OK Detail display Only for SET Effective Ineffective Keep pres...

Page 23: ...A B in order of input B A in order of input Second beam chan nel is effective Error OK NG Select send To 7 Sub sensor 2 Main sensor Sub sensor 1 Effective Ineffective To 6 To 6 Select sensor Check result Keep pressing switch OK It is possible to check ON OFF of all beam channels Effective beam channel Ineffective beam channel Select beam channel Effective Ineffective Muting lamp diagnosis setting ...

Page 24: ...tive When changing only the setting of the muting input condition set it by manual setting The input condition can be set at SE4D series respectively When initializing only the beam channel that the muting is effective set to the auto setting in the emission halt condition Notes 1 ALL is displayed only when set by Auto 2 Set the muting lamp diagnosis function on all SE4D series However if the func...

Page 25: ... the interlock Mode 0 Start restart interlock function factory setting Mode 1 Start interlock function Mode 2 Restart interlock function Mode 3 Ineffective Mode 0 Input password Mode 1 Mode 2 8 To External device monitor setting changing function Setting selection Mode 3 Send Error To 7 OK NG 7 Interlock setting changing function key operation FUNCTION ENTER CANCEL ...

Page 26: ...fective The external device monitor function is ineffective SET Effective The external device monitor function is effective The factory setting is 300ms Ineffective Effective 9 To Sub display function Protect function 8 External device monitor setting changing function Relay monitor setting Send Error To 8 OK NG Time setting 100ms 600ms 110ms 120ms Input pass word key operation FUNCTION ENTER CANC...

Page 27: ...on Initialization function 9 Sub display function Pro tect function Select sensor Sub sensor 1 Sub sensor 2 Select function Eeffctive Ineffctive Change password Input password Input new password Increase decrease the No with When the units are connected in series the indication is as follows CH1 CH2 CH3 key operation FUNCTION ENTER CANCEL ...

Page 28: ...sensors Main sensor 11 To Sub dis play function Setting con tents moni toring function 10 Sub display function Initialization function Select sensor Sub sensor 1 Sub sensor 2 Input password Send Error To 10 OK NG Confirm key operation FUNCTION ENTER CANCEL ...

Page 29: ...ive Effective Detail display Only for SET Keep pressing switch OK Effective Effective Note Emission intensity control function Positive logic of OSSD Auxiliary output switching function Protect function Fixed blanking function Floating blanking function Mode 1 Effective Model No No of beam channel CLR 100 to 600 unit of 10 Note Note Muting setting changing function Interlock setting changing funct...

Page 30: ...ting 60 sec 70 sec 80 sec 600 sec 9 To Sub display function Protect function 12 Override setting changing function Input pass word When two or more SE4D series are connected cancel the protective function of all SE4D series Note The factory setting is 60 sec key operation FUNCTION ENTER CANCEL ...

Page 31: ...stem configuration In the copy function download the data without uploading Upload the data before downloading The password does not match Input the correct password In case you forget the password contact us Note Sensor communication error 1 Model No is wrong Connect this device to SE4D series Sensor communication error 2 Wrong wiring between the emitter and receiver Connect the emitter and recei...

Page 32: ...k setting changing function External device monitor setting changing function Protective function Initialization function Setting contents monitoring function and Override setting changing function Ambient temperature 10 to 55 C No dew condensation or icing allowed Storage 25 to 70 C Ambient humidity 30 to 85 RH Storage 30 to 85 RH Voltage withstandability 1 000V AC for one minute between all supp...

Page 33: ...32 Revision history First edition January 10 2012 ...

Page 34: ...33 MEMO ...

Page 35: ...for use only in environments commonly found in manufacturing industry and unless expressly allowed in the catalogue specification or otherwise shall not be used in or incorporated into any equipment facilities or systems such as those a which are used for the protection of human life or body parts b which are used outdoors or in environments subject to any likelihood of chemical contamination or e...

Page 36: ...2012 2 http www idec com 7 31 Nishi Miyahara 1 Chome Yodogawa ku Osaka 532 8550 Japan Wendenstrasse 331 D 20537 Hamburg Germany IDEC ELEKTROTECHNIK GmbH ...

Reviews: