Functional Descriptions
<Minimum sensing object>
Floating blanking function
Ineffective
Effective
1 beam channel
2 beam channels
3 beam channels
SE4D-H
□
ø25mm
ø45mm
ø65mm
ø85mm
3-1-3 Auxiliary Output Switching Function
This function changes the operation state of the auxiliary output. It is useful when desired to make an
indicator to operate or inform the operation state of the
SE4D
series to PLC.
The following settings are selectable.
Setting
mode
Auxiliary output setting
Operation of the auxiliary output corresponding to
SE4D
series state
Emission
halt
State of sensing area when emitting
Lockout
Unshielded
Shielded
Unstable
light-receiving
condition
Others
0
Negative logic of the control
output (OSSD 1 / 2)
(factory setting)
ON
OFF when OSSD is ON
ON when OSSD is OFF
ON
1
Positive logic of the control
output (OSSD 1 / 2)
OFF
ON when OSSD is ON
OFF when OSSD is OFF
OFF
2
ON when emitting
OFF
ON
OFF
3
OFF when emitting
ON
OFF
ON
4
OFF under unstable light
receiving condition (Note 1)
(Note 3)
OFF
ON
(Note 3)
(Note 3)
5
ON under unstable light
receiving condition (Note 1)
(Note 3)
ON
OFF
(Note 3)
(Note 3)
6
ON during muting
OFF
ON during muting
Others: OFF
OFF
7
OFF during muting
ON
OFF during muting
Others: ON
ON
8
ON in light receiving condition
(Note 2)
OFF
ON
OFF
OFF
9
OFF in light receiving condition
(Note 2)
ON
OFF
ON
ON
Notes: 1) When the fixed blanking function, the floating blanking function or the muting function is used, the setting of ON / OFF
under unstable light-receiving condition does not work.
2) By the setting of ON / OFF in light receiving condition, light-receiving / light interrupted condition is output regardless of
the fixed blanking function, the floating blanking function or the muting function.
<e.g.>
When the fixed blanking function is used, if an obstacle exists in the set area and other area is in light receiving
condition, the control output (OSSD 1 / 2) is in ON sate, however, the auxiliary output becomes OFF since the
SE4D
series has been detecting the obstacle.
3) The state of the auxiliary output remains the same even if the
SE4D
series state changes.
If the floating blanking function is used, the incident light intensity indicator is turned OFF
when an obstacle exists in the sensing range regardless of the incident light intensity.
Do not use the auxiliary output for the purpose of stopping the machine in which the
SE4D
series
is installed. Failure to do so could result in death or serious injury.