SE2L User’s Manual (SE9Z-B1865)
51
For Safety distance calculation:
S
=
(K× ( Tm
+
Ts))
+
C
where:
S
= Safety distance (mm)
K
= Approach speed 1600 (mm/s)
T
m
= Maximum stopping/run-down time of the machine or system (s)
T
s
= Response time of SE2L (s)
C
= Additional distance of 850mm by considering arm intrusion (mm)
4.4 Access protection (Vertical application Stationary)
Figure 4-8 shows an example to prevent the access when part of the body is approached near the
hazardous area. If objects or part of body enters such area, OSSD signal switches to OFF state from ON-state.
SE2L detects an object or human being in vertical plane in such configuration. It is not possible to detect an
object or human being at the front or back side of the detection plane. Therefore, caution should be taken
while deciding the distance between approaching point and hazardous area. The width of protection zone
should be sufficient to protect the hazardous area. Always use reference monitor function in such
applications to detect the displacement of fences and SE2L which may expose the hazardous area. OSSD
signal will switch to OFF state when the position of reference is changed. The safety distance for this
application is shown in figure 4-8 and 4-9. Refer to section 7.15 for configuring the protection zone.
User should ensure that the width of unprotected
zone “a” is smaller than the
minimum detectable width. If the value of “a” is greater than minimum detectable
width, additional protective measures should be taken to prevent the penetration
through this unprotected zone.
In the access protection application where the angle of approach exceeds ±30º,
“Reference monitoring” function should be used with 100mm tolerance range for the
reference zone. Response time should be configured below 90ms in such application.
Reference segments should be configured on each sides of reference boundary.
SE2L should be mounted in such a way that accessibility towards hazardous point is
impossible. Use additional protective measures if necessary.
Tolerance should be taken in account when configuring the reference segments.
If minimum detectable width is configured as 30mm, value for C can be replaced
with 0.
Summary of Contents for SE2L Series
Page 1: ...SE9Z B1865 SE2L Series Safety Laser Scanner User s Manual ...
Page 100: ...SE2L User s Manual SE9Z B1865 99 Figure 7 31 b Function Figure7 31 c Area ...
Page 143: ...SE2L User s Manual SE9Z B1865 142 13 External dimension 13 1 SE2L H05LP mm ...
Page 144: ...SE2L User s Manual SE9Z B1865 143 13 2 SE2L H05LPC mm ...
Page 145: ...SE2L User s Manual SE9Z B1865 144 13 3 Base mounting bracket mm ...
Page 146: ...SE2L User s Manual SE9Z B1865 145 13 4 Rear mounting bracket mm ...
Page 147: ...SE2L User s Manual SE9Z B1865 146 13 5 Simple base mounting bracket mm ...
Page 149: ...SE2L User s Manual SE9Z B1865 148 13 7 Simple rear mounting bracket Long type mm ...
Page 150: ...SE2L User s Manual SE9Z B1865 149 13 8 Cover Protection Bracket mm ...