(image)
before
Some areas were
disabled even when
protection was needed
When light curtains are used
SE1L
Hazardous areas are
minimized, enhancing
safety
(image)
When laser scanner is used
Starts smoothly
No need
to remove
object
Override Function
Protection area
SE1L
Reference area
Moving
part
Moving
part
Floor
Protection
area
Reference
area
SE1L
Misalignment
Floor
Reference
area
SE1L
Object must be removed for restart
Remove
Object
No Override Function
Muting
Function
Override
Function
3
➁
Output OFF when mounting SE1L is misaligned
➀
Output OFF when
door opens
Override function enables safe restart of factory lines
Reference monitor function detects misalignment
Muting function enables flexible setting of protection zones
By configuring a reference point,
moving parts such as doors can
be detected when SE1L is not
correctly positioned, and turns off
the safety output (OSSD). Because
the misalignment of the SE1L can be
detected, hazardous areas can be
avoided, enhancing safety.
When a moving part is set as a reference point, the
output turns OFF when the door is opened.
With the override function, when a
light curtain is interrupted by an object
or when a line stops before muting
conditions are established (when only
one muting sensor is interrupted),
the object interrupting the light does
not have to be removed. Therefore,
the line can be started smoothly and
safely.
Specific areas of the protection zone
can be disabled by the muting sensor.
Complicated protection zones can be
configured easily.
(14/04/28)