IDEC PS3V Manual Download Page 12

PS3V Switching Power Supplies

1. Notes on contents of Catalogs

(1)  Rated values, performance values, and specification values of IDEC products 

listed in this Catalog are values acquired under respective conditions in 

independent testing, and do not guarantee values gained in combined 

conditions.  

Also, durability varies depending on the usage environment and usage 

conditions.

(2)  Reference data and reference values listed in Catalogs are for reference 

purposes only, and do not guarantee that the product will always operate 

appropriately in that range.

(3)  The specifications / appearance and accessories of IDEC products listed in 

Catalogs are subject to change or termination of sales without notice, for 

improvement or other reasons.

(4) The content of Catalogs is subject to change without notice.

2. Note on applications

(1)  If using IDEC products in combination with other products, confirm the 

applicable laws / regulations and standards.  

Also, confirm that IDEC products are compatible with your systems, machines, 

devices, and the like by using under the actual conditions. IDEC shall bear no 

liability whatsoever regarding the compatibility with IDEC products.

(2)  The usage examples and application examples listed in Catalogs are for 

reference purposes only. Therefore, when introducing a product, confirm the 

performance and safety of the instruments, devices, and the like before use. 

Furthermore, regarding these examples, IDEC does not grant license to use 

IDEC products to you, and IDEC offers no warranties regarding the ownership 

of intellectual property rights or non-infringement upon the intellectual 

property rights of third parties.

(3) When using IDEC products, be cautious when implementing the following.

i.  Use of IDEC products with sufficient allowance for rating and  

 

performance
ii.   Safety design, including redundant design and malfunction prevention 

design that prevents other danger and damage even in the event that an 

IDEC product fails

iii.   Wiring and installation that ensures the IDEC product used in your 

system, machine, device, or the like can perform and function according 

to its specifications

(4)  Continuing to use an IDEC product even after the performance has 

deteriorated can result in abnormal heat, smoke, fires, and the like due to 

insulation deterioration or the like. Perform periodic maintenance for IDEC 

products and the systems, machines, devices, and the like in which they are 

used.

(5)  IDEC products are developed and manufactured as general-purpose products 

for general industrial products. They are not intended for use in the following 

applications, and in the event that you use an IDEC product for these 

applications, unless otherwise agreed upon between you and IDEC, IDEC shall 

provide no guarantees whatsoever regarding IDEC products.

i.   Use in applications that require a high degree of safety, including nuclear 

power control equipment, transportation equipment (railroads / airplanes 

/ ships / vehicles / vehicle instruments, etc.), equipment for use in outer 

space, elevating equipment, medical instruments, safety devices, or 

any other equipment, instruments, or the like that could endanger life or 

human health

ii.   Use in applications that require a high degree of reliability, such as 

provision systems for gas / waterworks / electricity, etc., systems that 

operate continuously for 24 hours, and settlement systems

iii.   Use in applications where the product may be handled or used deviating 

from the specifications or conditions / environment listed in the Catalogs, 

such as equipment used outdoors or applications in environments 

subject to chemical pollution or electromagnetic interference  

If you would like to use IDEC products in the above applications, be sure 

to consult with an IDEC sales representative.

3. Inspections

We ask that you implement inspections for IDEC products you purchase without 

delay, as well as thoroughly keep in mind management/maintenance regarding 

handling of the product before and during the inspection.

4. Warranty

(1) Warranty period

The warranty period for IDEC products shall be five (5) years after purchase or 

delivery to the specified location. However, this shall not apply in cases where 

there is a different specification in the Catalogs or there is another agreement 

in place between you and IDEC.

(2) Warranty scope

Should a failure occur in an IDEC product during the above warranty period 

for reasons attributable to IDEC, then IDEC shall replace or repair that 

product, free of charge, at the purchase location / delivery location of the 

product, or an IDEC service base. However, failures caused by the following 

reasons shall be deemed outside the scope of this warranty.
i.  The product was handled or used deviating from the conditions /  

 

environment listed in the Catalogs
ii.  The failure was caused by reasons other than an IDEC product
iii.  Modification or repair was performed by a party other than IDEC
iv.  The failure was caused by a software program of a party other than  

 

IDEC
v.  The product was used outside of its original purpose
vi.   Replacement of maintenance parts, installation of accessories, or the like 

was not performed properly in accordance with the user’s manual and 

Catalogs

vii.  The failure could not have been predicted with the scientific and  

 

technical standards at the time when the product was shipped from  

 

IDEC
viii.   The failure was due to other causes not attributable to IDEC (including 

cases of force majeure such as natural disasters and other disasters)

Furthermore, the warranty described here refers to a warranty on the IDEC 

product as a unit, and damages induced by the failure of an IDEC product are 

excluded from this warranty.

5. Limitation of liability

The warranty listed in this Agreement is the full and complete warranty for IDEC 

products, and IDEC shall bear no liability whatsoever regarding special damages, 

indirect damages, incidental damages, or passive damages that occurred due to an 

IDEC product.

6. Service scope

The prices of IDEC products do not include the cost of services, such as dispatching 

technicians. Therefore, separate fees are required in the following cases.

(1)  Instructions for installation / adjustment and accompaniment at test operation 

(including creating application software and testing operation, etc.)

(2) Maintenance inspections, adjustments, and repairs
(3) Technical instructions and technical training
(4) Product tests or inspections specified by you

  The above content assumes transactions and usage within your region. Please 

consult with an IDEC sales representative regarding transactions and usage outside 

of your region. Also, IDEC provides no guarantees whatsoever regarding IDEC 

products sold outside your region.

Ordering Terms and Conditions

Thank you for using IDEC Products.
By purchasing products listed in our catalogs, datasheets, and the like (hereinafter referred to as “Catalogs”) you agree to be bound by these terms and conditions. Please read 

and agree to the terms and conditions before placing your order.

Specifications and other descriptions in this brochure are subject to change without notice.

Information in this catalog is current as of June, 2021.

2021 IDEC Corporation, All Rights Reserved. 
EP1751-2-A

apac.idec.com

IDEC CONTROLS INDIA PRIVATE LIMITED

2201A, 22nd Floor, WTC Bangalore, 
Brigade Gateway, Rajaji Nagar Extension, 
Malleswaram, Bengaluru, KA 560055 India
Tel: +91-80679-35328
E-mail: [email protected]

IDEC ASIA (THAILAND) CO., LTD.

20th Fl., Sorachai Bldg., No.23/78, Soi Sukhumvit 63, 
Sukhumvit Rd., Klongton-nua, Wattana, Bangkok 10110
Tel: +662-392-9765, Fax: +662-392-9768
E-mail: [email protected]

IDEC IZUMI ASIA PTE. LTD.

No. 31, Tannery Lane #05-01, HB Centre 2, 
Singapore 347788
Tel: +65-6746-1155, 
Fax: +65-6844-5995
E-mail: [email protected]

Summary of Contents for PS3V

Page 1: ...Switching Power Supplies PS3V Compact Reliable Power Supplies Flexible installation allows mounting in four directions ...

Page 2: ...ilities such as buildings Operates in temperatures ranging from 25 to 70 C Ideal for use in various storage facilities such as freezers and refridgerators Warehouse storage Compact Operating Temperature Push in connection As a manufacturer of factory automation products we provide total solutions and related PLCs HMI products One step wiring Safe and effiecient push in connection Push in models av...

Page 3: ...rage Car facilities Logistics and transport facilities Agricultural facilities Energy related facilities others QR codes are printed on the product enabling easy access to the latest instruction manuals Safety Standards Mounting examples When PS3V 030AF is mounted standard mount with PS9Z 3E3C mounting bracket Direct mount DIN rail mount When PS3V 050AF is mounted standard mount with PS9Z 3E3B mou...

Page 4: ...PS3X L shaped mounting brackets PS9Z 3N3B cannot be used L shaped mounting bracket is not available for PS3V 150AF PS9Z 3N3B L shaped mounting brackets cannot be used for PS3V 150AF Part no configuration DIN rail End clip Tools Specify the Ordering no when ordering Name Part No Ordering No Package quantity Remarks 35mm DIN rail BAA1000 BAA1000PN10 10 Material Aluminum Weight 200g Length 1 000mm En...

Page 5: ...x 12V 2 5 p p max 24V 1 5 p p max 12V 2 5 p p max 24V 1 5 p p max 24V 1 5 p p max 0 to 50 C 5V 2 5 p p max 12V 1 5 p p max 24V 1 p p max 5V 2 5 p p max 12V 1 5 p p max 24V 1 p p max 12V 1 5 p p max 24V 1 p p max 24V 1 p p max Supplementary functions Overcurrent protection 105 min auto reset 2 Overvoltage protection 120 min intermittent auto reset Output off at 120 min reset when re input Operation...

Page 6: ... 85 100 264 0 10 20 30 40 50 60 70 80 90 100 85 90 264 0 20 40 60 80 100 Input Voltage VAC 85 100 264 0 20 40 60 80 100 Output Current Input Voltage VAC Output Current Input Voltage VAC Output Current PS3V 015AF 030AF PS3V 050AF Areas indicated with may take time for the output voltage to stabilize Overcurrent detection Detection L N INPUT Control Line filter Switching Fuse Rectifier Rectifier V A...

Page 7: ...F Note Note the terminal arrangement when wiring AC L AC N V V V ADJ LED AC L AC N V V V ADJ LED AC L AC N V V V ADJ LED AC L AC N V V V ADJ LED AC L AC N V V V ADJ LED V V AC L AC N V V V ADJ LED V AC L AC N V V V V ADJ LED AC L AC N V V V V ADJ LED AC L AC N V V V V V V V ADJ LED PS3V 050AF PS3V 030AF PS3V 100AF PS3V 100AF Horizontal terminal type Push in terminal type Note 15W is not available ...

Page 8: ... Depth 6mm max 2 M3 Depth 6mm max 8 2 9 5 Terminal Centers 17 10 5 80 34 5 2 M3 95 5 68 5 101 2 M3 36 5 15 70 7 5 Input terminal centers Depth 6mm max 5 0 Output terminal centers Depth 6mm max 80 45 5 23 5 55 99 17 5 7 74 36 2 M3 2 M3 104 5 7 5 Input terminal centers 5 0 Output terminal centers Depth 6mm max Depth 6mm max 108 49 93 12 5 76 10 18 14 77 19 39 3 M3 113 5 2 M3 7 5 Input terminal cente...

Page 9: ...lectric Facilities for General Use When using the product follow the following precautions Precautions on switching power supplies This product is for industrial or general electronic equipment such as communication measurement and industrial electronic equipment Do not use for devices that may cause malfunction or may harm the body or threaten human life Make sure that the input voltage and outpu...

Page 10: ... supplies operate normally when voltage returns to normal PS3X 030 050 100 150 The output is turned off or intermittent operation when an overvoltage is applied When the output voltage has dropped due to an overvoltage turn the input off and after one minute turn the input on again Insulation Dielectric test When performing an insulation dielectric test short the input between AC and output betwee...

Page 11: ...al disasters Warranty Accessories and wiring for Push in terminals Wire size and recommended ferrules Push in terminal type only Ferrules with insulated covers Applicable Wire Stranded Wire Wire Strip Length mm Part No Ordering No AWG mm2 For 1 wire 18 0 75 12 S3TL H075 16WW 17 1 0 12 S3TL H10 16WY 16 1 5 12 S3TL H15 16WR For 2 wires 18 0 75 21 S3TL J075 19WWS Recommended tools Optional See page 4...

Page 12: ...spections We ask that you implement inspections for IDEC products you purchase without delay as well as thoroughly keep in mind management maintenance regarding handling of the product before and during the inspection 4 Warranty 1 Warranty period The warranty period for IDEC products shall be five 5 years after purchase or delivery to the specified location However this shall not apply in cases wh...

Reviews: