13: T
ROUBLESHOOTING
13-10
W
EB
S
ERVER
CPU M
ODULE
U
SER
’
S
M
ANUAL
FC9Y-B1278
Troubleshooting Diagram 2
Is stop or reset input
designated using Function
Area Settings?
Click the Start button in WindLDR on a
computer connected to the Web server
CPU module.
Is the ERR LED on?
See Troubleshooting Diagram 3,
“The ERR LED is on.”
Is the RUN LED on?
Monitor M8000 (start control special
internal relay) using WindLDR.
Is M8000 on?
Turn on M8000 using WindLDR.
Is the RUN LED on?
Turn off the stop and reset inputs.
Is the RUN LED on?
Note:
The Start button is found in the WindLDR menu bar.
Note:
To monitor M8000, from the WindLDR menu bar, select
Online > Monitor > Monitor, then Online > Custom > New
Custom Monitor. Enter M8000 in the Device box in the Custom
Monitor dialog box.
Note:
To turn on M8000, enter 1 in the Current Value box in
the Custom Monitor dialog box.
YES
YES
YES
YES
YES
YES
NO
NO
NO
NO
NO
NO
END
Call IDEC for assistance.
The RUN LED does not go on.