background image

 

1

B-1243(5) 

 

 

INSTRUCTION SHEET 

Operator Interface 

                          HG2G Series 

 

Confirm that the delivered product is what you have ordered. Read this instruction sheet to make 
sure of correct operation. Make sure that the instruction sheet is kept by the end user. 

 

SAFETY PRECAUTIONS

 

In this operation instruction sheet, safety precautions are categorized in order of importance to 
Warning and Caution: 
 

 

Warning notices are used to emphasize that improper operation may cause severe personal 
injury or death. 
 

 

Caution notices are used where inattention might cause personal injury or damage to equipment. 
 
 
 

 

When using the HG2G in applications which require high reliability and safety, such as 
nuclear equipment, railways, aircraft, medical equipment, and vehicles, add a failsafe or 
backup functionality and verify an adequate level of safety using the product specifications. 

 

Turn off the power to the HG2G before installation, removal, wiring, maintenance, and 
inspection of the HG2G. Failure to turn power off may cause electrical shock or fire hazard. 

 

Special expertise is required to install, wire, configure, and operate the HG2G. People 
without such expertise must not use the HG2G. 

 

The HG2G uses an LCD (liquid crystal display) as a display device. The liquid inside the 
LCD is harmful to the skin. If the LCD is broken and the liquid attaches to your skin or clothes, 
wash the liquid off using soap, and consult a doctor immediately. 

 

Emergency and interlocking circuits must be configured outside the HG2G. 

 

Replace battery with UL recognized battery, model CR2032 only. Use of another battery may 
present a risk of fire or explosion. See instruction sheet for safety instructions. 

 
 
 

 

Install

 

the HG2G according to the instructions in the Instruction Manual. Improper installation 

will result in falling, failure, electrical shock, fire hazard, or malfunction of the HG2G. 

 

The HG2G is designed for use in pollution degree 2. Use the HG2G in environments of 
pollution degree 2. 

 

The HG2G uses “PS2 of EN61131” as DC power supply. 

 

Prevent the HG2G from falling while moving or transporting, otherwise damage or 
malfunction of the HG2G will result. 

 

Prevent metal fragments or wire chips from dropping inside the HG2G housing. Ingress of 
such fragments and chips may cause fire hazard, damage, and malfunction. 

 

Use a power supply of the rated value. Using a wrong power supply may cause fire hazard. 

 

Use wire of a proper size to meet the voltage and current requirements.   

 

Use fuses or circuit protectors on the power line outside the HG2G. 

 

When exporting the HG2G to Europe, use an EN60127 ( EC60127) approved fuse or an 
EU-approved circuit protector. 

 

Do not push hard or scratch the touch panel and protection sheet with a hard object such as 
a tool, because they are damaged easily. 

 

Make sure of safety before starting and stopping the HG2G. Incorrect operation of the HG2G 
may cause mechanical damage or accidents. 

 

When disposing of the HG2G, do so as an industrial waste. 

 

UL/c-UL Compliance and Handling Cautions 

 

This equipment is suitable for use in Class

, Division 2, Groups A, B, C, D or 

Non-Hazardous locations only. 

 

Warning - Explosion Hazard - Substitution of components may impair suitability for Class I, 
Division 2 

 

Warning - Explosion Hazard - Do not disconnect equipment unless power has been 
switched off or the area is known to be Non-Hazardous. 

 

Replace battery with UL recognized battery, model CR2032 or CR2032H only. Use of another 
battery may present a risk of fire or explosion. See instruction sheet for safety instructions. 

 

Caution - Battery may explode if mistreated. Do not recharge, disassemble or dispose of in 
fire. 

 

Warning - Explosion Hazard – Batteries must only be changed in an area known to be 
Non-Hazardous. 

 

For Indoor Use Only, Pollution Degree 2 Environment, in an area that is dry and free of 
contaminates. 

 

 

Avertissement: Risque d'explosion. La substitution de composants peut rendre ce matériel 
inacceptable pour les emplacements de classe I, division 2. 

 

Avertissement: Risque d'explosion. Avant de déconnecter l'equipement, couper le courant 
ou s'assurer que l'emplacement est désigné non dangereux. 

 

Avertissement: Risque d'explosion. Afin d'éviter tout risque d'explosion, s'assurer que 
l'emplacement est désigné non dangereux avant de changer la batterie. 

 

Attention: Risque d’explosion de la batterie en cas de mauvaise utilisation. Ne pas recharger, 
démonter ou jeter la batterie au feu. 

 
 

1

 

Package Content 

 

Before installing the HG2G, make sure that the specifications of the product conform to your 
requirements, and that no parts are missing or damaged due to accidents during transportation. 
 

 
 

Main Unit (24VDC Type)

 

Display Device 

Interface 

Model No. 

5.7-inch 
STN color LCD 

RS232C, RS422/485 

HG2G-SS22VF-

 

RS232C, RS422/485   

& Ethernet 

HG2G-SS22TF-

 

5.7-inch 
STN monochrome LCD

RS232C, RS422/485 

HG2G-SB22VF-

 

RS232C, RS422/485   

& Ethernet 

HG2G-SB22TF-

 

 

indicates the bezel color. 

Main Unit (12VDC Type)

 

Display Device 

Interface 

Model No. 

5.7-inch 
STN color LCD 

RS232C, RS422/485 

HG2G-SS21VF-

 

RS232C, RS422/485   

& Ethernet 

HG2G-SS21TF-

 

5.7-inch 
STN monochrome LCD

RS232C, RS422/485 

HG2G-SB21VF-

 

RS232C, RS422/485   

& Ethernet 

HG2G-SB21TF-

 

 

indicates the bezel color.

 

Accessories 

Mounting Clip (4) 

Host communication plug (1) 
(Attached to the Main Unit) 

Instruction Sheet (Japanese/English) 
[This manual] 1 each 

 

 

2

 

Type No. Development 

 

HG2G-S#2$*F-% 

 

#  Display  S: STN color LCD 

               B: STN monochrome LCD 
 

$  Power supply  2: 24VDC 

                                        1: 12VDC 
 

*  Interface  V: RS232C, RS422/485 

                T: RS232C, RS422/485 & Ethernet 
 

%  Bezel color  W: Light gray 

                                      B: Dark gray 
                                      S: Silver 
 

3

 

Specifications 

 
 

Safety Standards 

UL508, ANSI/ISA 12.12.01 
CSA C22.2 No.142    CSA C22.2 No.213 
IEC/EN61131-2 

EMC Standards 

IEC/EN61131-2 

 

Electrical

 S

pecif

icatio

ns 

Rated Operating Voltage 

HG2G-S#22*F-% : 24V DC 
HG2G-S#21*F-% : 12V DC 

Power Voltage Range 

HG2G-S#22*F-%  

85% to 120% of the rated voltage (24VDC)

HG2G-S#21*F-%  

85% to 150% of the rated voltage (12VDC)

(including ripple) 

Power Consumption 

10W maximum 

Allowable Momentary 
Power Interruption 

10 ms maximum, Level: PS-2 
( EC/EN61131) 

Inrush Current 

HG2G-S#22*F-% : 20A maximum 
HG2G-S#21*F-% : 40A maximum 

Dielectric Strength 

1000V AC, 10 mA, 1 minute 
(between power terminals and FG) 

Insulation Resistance 

50 M

 minimum (500V DC megger) 

(between power terminals and FG) 

Backup Battery 

Built-in CR2032 lithium primary battery 
Standard replacement cycle: 5 years 
Guaranteed term: 1 year (at 25°C) 

Environ

men

tal S

p

ecif

ications

 

Operating Ambient Temperature 

0 to 50°C

 

Operating Relative Humidity 

10 to 90% RH (no condensation) 

Storage Ambient Temperature 

-20 to 60°C 

Storage Relative Humidity 

10 to90% RH (no condensation) 

Altitude 

0 to 2000m (operation) 
0 to 3000m (transportation) (IEC61131-2) 

Vibration Resistance 
(Damage Limits) 

5 to 9 Hz, amplitude 3.5 mm
9 to 150 Hz, 9.8 m/s

X, Y, Z directions for 10 cycles [100 minutes]
 (IEC60068-2-6) 

Shock Resistance 
(Damage Limits) 

147 m/s

2

, 11 ms 

5 shocks each in 3 axes (IEC60068-2-27) 

Pollution Degree 

2 (IEC60664-1) 

Corrosion Immunity 

Free from corrosive gases 

Construc

tion 

S

pecificat

ions

 

Degree of Protection 

P65  *1 

TYPE 13  *2 
(In the front of panel attachment.) 

Terminal 

Power supply terminal: M3 
Tightening torque 0.5 to 0.6 N

Dimensions 

167.2 (W) × 134.7 (H) × 40.9 (D) mm 

Weight (Approx.) 

500g 

Summary of Contents for MICRO/I HG2G Series

Page 1: ...sion See instruction sheet for safety instructions Caution Battery may explode if mistreated Do not recharge disassemble or dispose of in fire Warning Explosion Hazard Batteries must only be changed in an area known to be Non Hazardous For Indoor Use Only Pollution Degree 2 Environment in an area that is dry and free of contaminates Avertissement Risque d explosion La substitution de composants pe...

Page 2: ...Operation The screen becomes blank when the backlight is burnt out however the touch panel remains enabled Incorrect touch panel operation will occur when operating the touch panel when the backlight appears to be turned off but is actually burnt out Note that this erroneous operation may result in damage At temperatures over the rated operating temperature the clock accuracy is affected Adjust th...

Page 3: ... Dedicated connector The HG2G Operator Interface can be connected to an O I Link Unit for 1 N communication with a PLC This allows high speed communication with the PLC host Ethernet interface EEE802 3 standard compliant 10 100Base T No Name O Function 1 TPO OUT Send Data 2 TPO OUT Send Data 3 TPI IN Receive Data 4 NC No Connection 5 NC No Connection 6 TPI IN Receive Data 7 NC No Connection 8 NC N...

Page 4: ...ears on the screen 2 Press the Adjust Contrast at the bottom of the Maintenance Screen The Adjust Contrast Screen appears 3 Press the or at the bottom the Adjust Contrast Screen to adjust the contrast to the optimal setting 4 Press the X to close the Adjust Contrast Screen The Maintenance Screen is not displayed in System Mode To adjust the contrast in System Mode use the and buttons located at th...

Reviews: