Engineering
40
HR9Z-B2202 8/2020
Safety-Related Inputs
Overview
The following sections provide basic information on the safety-related inputs such as principle of
activation and deactivation as well as antivalent behavior. Refer to the chapters Electrical
Characteristics
) and Electrical Installation (
) for more details on the
safety-related inputs.
General Information on Activation and Deactivation of Safety-Related Inputs
In the present document, “activation” of a safety-related input means that a safety-related input
changes its state so that the device can enter the operating state Run: Outputs Energized.
The term “deactivation” of a safety-related input means that a safety-related input changes its state
so that the device enters the operating state Run: Outputs Deenergized.
See Operating States
) for details on the state machine of the device.
Activation and Deactivation with Antivalent Behavior Between Two Input Channels of One Safety-Related
Input
Depending on the selected application function, the input channels of the safety-related input are
configured for antivalent behavior. Antivalent is defined here as a normally open and a normally
closed contacts working in synchronization.
For example, for application function 5
), the signal for input channel S12 is provided
by a normally open contact, whereas the signal for input channel S13 is provided by a normally
closed contact.
WARNING
INSUFFICIENT AND/OR INEFFECTIVE SAFETY-RELATED FUNCTIONS
Only connect a sensor/device to a safety-related input that meets all requirements as per your
risk assessment and that complies with all regulations, standards, and process definitions
applicable to your machine/process.
Failure to follow these instructions can result in death, serious injury, or equipment damage.
Summary of Contents for HR6S-S
Page 1: ...http www idec com HR6S S Safety Module Original instructions HR9Z B2202 ...
Page 8: ...8 HR9Z B2202 8 2020 ...
Page 14: ...14 HR9Z B2202 8 2020 ...
Page 20: ...Introduction 20 HR9Z B2202 8 2020 ...
Page 56: ...Installation 56 HR9Z B2202 8 2020 ...
Page 92: ...Accessories Service Maintenance and Disposal 92 HR9Z B2202 8 2020 ...