Diagnostics
HR9Z-B2200 8/2020
89
0010101100
Cross circuit detected at
input terminal S33.
Verify correct wiring.
Verify that the sensor/device providing the input signal is
suitable for cross circuit detection by means of
dynamization. If it is not, use an application function
without dynamization or a sensor/device suitable for
dynamization.
Verify correct operation of sensor/device providing the
input signal.
Perform a power cycle.
E
0010011011
Cross circuit detected at
input terminal S42.
Verify correct wiring.
Verify that the sensor/device providing the input signal is
suitable for cross circuit detection by means of
dynamization. If it is not, use an application function
without dynamization or a sensor/device suitable for
dynamization.
Verify correct operation of sensor/device providing the
input signal.
Perform a power cycle.
E
0010011010
Cross circuit detected at
input terminal S43.
Verify correct wiring.
Verify that the sensor/device providing the input signal is
suitable for cross circuit detection by means of
dynamization. If it is not, use an application function
without dynamization or a sensor/device suitable for
dynamization.
Verify correct operation of sensor/device providing the
input signal.
Perform a power cycle.
E
0010011110
Cross circuit detected at
input terminal S52.
Verify correct wiring.
Verify that the sensor/device providing the input signal is
suitable for cross circuit detection by means of
dynamization. If it is not, use an application function
without dynamization or a sensor/device suitable for
dynamization.
Verify correct operation of sensor/device providing the
input signal.
Perform a power cycle.
E
0010011111
Cross circuit detected at
input terminal S53.
Verify correct wiring.
Verify that the sensor/device providing the input signal is
suitable for cross circuit detection by means of
dynamization. If it is not, use an application function
without dynamization or a sensor/device suitable for
dynamization.
Verify correct operation of sensor/device providing the
input signal.
Perform a power cycle.
E
Bit sequence
Description
Correctives
Type
(1)
(1) Type of message: E = Error detected, A = Alert, S = Status information
Summary of Contents for HR6S-DN
Page 1: ...http www idec com HR6S DN Safety Module Original instructions HR9Z B2200...
Page 8: ...8 HR9Z B2200 8 2020...
Page 14: ...14 HR9Z B2200 8 2020...
Page 20: ...Introduction 20 HR9Z B2200 8 2020...
Page 56: ...Installation 56 HR9Z B2200 8 2020...
Page 64: ...Functions 64 HR9Z B2200 8 2020 Wiring of the inputs for coded magnetic switches...
Page 66: ...Functions 66 HR9Z B2200 8 2020 Wiring of the inputs for coded magnetic switches...
Page 69: ...Functions HR9Z B2200 8 2020 69 Wiring of the inputs for sensors devices with two PNP outputs...
Page 72: ...Functions 72 HR9Z B2200 8 2020 Wiring of the inputs for sensors devices with OSSD outputs...
Page 98: ...Accessories Service Maintenance and Disposal 98 HR9Z B2200 8 2020...