User Guide PPS-TWIN
V1.0 - Module V1.7
1.
2.
Page 3
0.34
22
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
0.5
20
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
0.75
18
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
1.5
16
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
2.5
14
1.2m
4 Feet
1m
3.5 Feet
0.9m
3 Feet
0.9m
3 Feet
0.9m
3 Feet
X
X
X
X
X
X
X
X
4
12
1.8m
6 Feet
1.7m
5.5 Feet
1.5m
5 Feet
1.5m
5 Feet
1.3m
4.5 Feet
1.2m
4 Feet
1.2m
4 Feet
1m
3.5 Feet
1m
3.5 Feet
6
10
3.0m
10 Feet
2.7m
9 Feet
2.4m
8 Feet
2.2m
7.5 Feet
2.1m
7 Feet
2m
6.5 Feet
1.8m
6 Feet
1.8m
6 Feet
1.6m
5.5 Feet
10
8
4.7m
15.5 Feet
4.2m
14 Feet
4m
13 Feet
3.6m
12 Feet
3.3m
11 Feet
3.2m
10.5 Feet
3m
10 Feet
2.7m
9 Feet
2.5m
8.5 Feet
16
6
7.6m
25 Feet
6.8m
22.5 Feet
6.2m
20.5 Feet
5.8m
19 Feet
5.3m
17.5 Feet
5m
16.5 Feet
4.7m
15.5 Feet
4.4m
14.5 Feet
4.2m
14 Feet
25
4
12m
39.5 Feet
11m
36 Feet
10m
33 Feet
9.2m
30.5 Feet
8.5m
28 Feet
8m
26.5 Feet
7.4m
24.5 Feet
7m
23 Feet
6.7m
22 Feet
35
2
19.2m
63 Feet
17.3m
57 Feet
16m
52.5 Feet
14.7m
48.5 Feet
13.7m
45 Feet
12.8m
42 Feet
11.8m
39 Feet
11.2m
37 Feet
10.6m
35 Feet
50A
55A
60A
65A
70A
75A
80A
85A
90A
0.34
22
1.8m
6 Feet
0.9m
3 Feet
X
X
X
X
X
X
X
X
X
X
X
X
X
X
0.5
20
2.9m
9.5 Feet
1.5m
5 Feet
0.9m
3 Feet
X
X
X
X
X
X
X
X
X
X
X
X
0.75
18
4.5m
15 Feet
2.2m
7.5 Feet
1.5m
5 Feet
1.2m
4 Feet
0.9m
3 Feet
X
X
X
X
X
X
X
X
1.5
16
7.5m
24.5 Feet
3.5m
12 Feet
2.4m
8 Feet
1.8m
6 Feet
1.5m
5 Feet
1.2m
4 Feet
1m
3.5 Feet
0.9m
3 Feet
X
X
2.5
14
12m
39 Feet
6m
19.5 Feet
4m
13 Feet
2.8m
9.5 Feet
2.5m
8 Feet
2m
6.5 Feet
1.6m
5.5 Feet
1.5m
5 Feet
1.3m
4.5 Feet
4
12
20m
62 Feet
9.5m
31 Feet
6m
20.5 Feet
4.7m
15.5 Feet
3.8m
12.5 Feet
3.2m
10.5 Feet
2.7m
9 Feet
2.3m
7.5 Feet
2.1m
7 Feet
6
10
30m
98 Feet
15m
49 Feet
10m
32.5 Feet
7.5m
24.5 Feet
6m
19.5 Feet
5m
16.5 Feet
4.2m
14 Feet
3.8m
12.5 Feet
3.3m
11 Feet
10
8
48m
156 Feet
24m
78 Feet
16m
52 Feet
11.8m
39 Feet
9.4m
31 Feet
8m
26 Feet
6.8m
22.5 Feet
5.9m
19.5 Feet
5.3m
17.5 Feet
16
6
75m
248 Feet
37m
124 Feet
25m
82.5 Feet
18.8m
62 Feet
15m
49.5 Feet
12.6m
41.5 Feet
10m
35.5 Feet
9.4m
31 Feet
8.3m
27.5 Feet
25
4
120m
395 Feet
60m
197 Feet
40m
131 Feet
30m
98.5 Feet
24m
79 Feet
20m
66 Feet
17m
56.5 Feet
15m
49.5 Feet
13.4m
44 Feet
35
2
190m
629 Feet
95m
314 Feet
63m
209 Feet
47m
157 Feet
38m
125 Feet
31m
104 Feet
27m
89.5 Feet
2.9m
78.5 Feet
21m
69.5 Feet
5A
10A
15A
20A
25A
30A
35A
40A
45A
X
Fig.1
FILS
mm² AWG
FILS
mm² AWG
MAXIMUM AUTHORISED CURRENT IN THE WIRES
MAXIMUM AUTHORISED CURRENT IN THE WIRES
ABACUS FOR THE DIMENSIONING OF ELECTRIC WIRES
It is essential and mandatory to dimension electrical wires correctly according to the currents used and the length of the wires. Failure to dimension
correctly may cause fire inside the vehicle. The product is equipped with static relay outputs only. The use of static relays has several advantages,
among which the suppression of external fuses.
The cable connected to the + terminal of the PPS-TWIN must be protected by a fuse calculated on the basis of the total current consumed according
to the configuration (maximum 40A). Its section must be sufficient to support this current.
To fix the wire size, you must follow three essential precautions:
R
Know or determine the maximum current consumed at each static output.
R
Setup each static output used to limit the maximum current from 0,5 to 10A thanks to the software provided by IDEATEC S.A..
R
Select the wire gauge according to its length and the current absorbed using the chart below :
Dimensioning of electric wires
Safety and precautions (continued)
= Insufficient
I
Check that any inductive load connected to the PPS-TWIN is equipped with an overvoltage protection diode (see diagram below) which absorbs
reverse voltage peak that can be destructive. Inductive load can be motor, water pump, vacuum cleaner, fan, contactor, etc. In case of doubt, it is
imperative to consult your reseller or Ideatec. If free output is available to the user (+ 12V socket, cigarette lighter socket, etc.), the overvoltage
protection diode must be fitted. The diode must have a reverse avalanche voltage threshold (Vrm) equal to or greater than 33V, for example diode
BZW50-33. Any inverter type load connection is strictly prohibited.
I
Failure to follow safety guidelines and instructions may cause material damages, injuries, or death to you and/or to others.
I
All IDEATEC metal cases must be grounded correctly to the negative battery. Never defeat the ground conductor or operate the equipment in the
absence of a suitably installed ground conductor. Ideatec provides a kit REF.P0035F0034 to make this connection. The connection must be made
on one of the flanges of the Ideatec system as shown in figure 1. The tooth washers must be positioned on either side of the terminal as shown in
figure 1. The terminal provided allows a cable cross-section of 4 mm² to 6mm³, however Ideatec SA requires the placement of a 6mm² cable with
a maximum length of 50cm.
IDEATEC S.A. assumes no liability and give the right to refuse any warranty if one or more of the
recommendations on page 2 and 3 are not being followed.
POWER POSITIVE OUTPUT