- 7 -
CLEANING AND MAINTENANCE
In case when the water is hard which means water contains too much calcium and magnesium, they can cause
“white powder (limestone)” problem and may cause heavy sediments on the surface of the water basin,
transducer and inner surface of the water tank. Sediments on the surface of the transducer could influence proper
function.
We recommend:
1)
Use cold boiled water or distilled water.
2)
Clean the transducer, water tank and basin unit every week.
3)
Change water in water tank frequently to avoid “white powder” / limestone.
4)
Pour away the water first, clean the whole unit, and make sure that all parts of the unit are dried completely
before storing the unit for a long period of time. Keep the appliance away from children in a dry cool place.
Caution: before cleaning and filling, turn off and unplug the appliance first.
How to clean the transducer:
1)
Put 5-10 drops of decalcifying agent or citric acid on the surface of the transducer; wait for 2-5 minutes.
2)
Brush off the scale deposit from the surface and then rinse the transducer with clean water.
3)
Never use sharp or solid objects to clean the transducer.
How to clean the water basin:
1)
Clean the water basin with soft cloth or use citric acid if there is scale in it.
2)
If the scale is covered on the buoy, drop citric acid for 2-5 mins on the scale and clean it out with a brush.
3)
Rinse the water basin with clean water.
How to clean the ceramic filter:
1)
Clean the ceramic filter after using 1000L water regularly. Depend on the water quality, if the ceramic balls
are dirty, the filter needs to be cleaned more frequently.
2)
It can be dipped in vinegar about 5 minutes. Then rinse it with clean water.
3)
Put the filter under the sun for 4~6 hours.
TROUBLE SHOOTING GUIDE
Any trouble found in normal operation; please kindly refer to the following points:
Trouble
Possible Cause
Solution
Indicator light is off when
switched on.
Humidifier is not plugged in.
Plug the humidifier into a
powered electrical socket.
Power cord is damaged.
Immediately discontinue use and
contact customer support.
Humidifier is defective or
malfunctioning.
Indicator light is in red.
No water in the tank.
Refill the water tank and wait at
least 1 minute.
Water level is low.
The water level required has not
yet reached the water basin.
Wait at least 1 minute.
The water tank isn’t well
positioned.
Check the positioning of tank on
the base.
The humidifier isn’t on a flat
surface.
Check the positioning of the
humidifier.
Humidifier produces an unusual
smell.
Humidifier is new.
Take out water tank, open cover,
let it stay 12 hours in cool
position.