6

Service (Qualified personnel only)

Replacement/Adjustment

Blade Installation

1.   Disconnect the unit from air supply and turn power switch off.
2.   Remove the four socket head screws (use  7/64 hex wrench) 

located at the corners of the front cover plate.

5.  Install the blade halves. Insert the #4-40 button head cap 

screw (use 1/16 hex wrench) and lock washers but do not 
tighten completely. 

6.   Back out all (6) set screws (use .050 hex wrench) located at 

the bottom of the blade holder.

WARNING: Keep fingers away from the blade area.

7.   Connect air supply and turn power switch on. Switch the AUTO 

SET-UP switch to the SET-UP position. This will close all blades 
firmly.

8.   Check all blade sets for gaps. Adjust blade set screws accord-

ingly to ensure proper seating of blade sets. Care must be taken 
not to over extend any one blade. This will result in gaps in 
remaining blade sets. 

9.   With blades properly adjusted, tighten all blade holding screws. 
10.  Reconnect air line to the face plate 

by inserting hose into the com-
pression fitting firmly.

11.   Reinstall front cover plate, making 

sure clamp dowel pins are  
properly aligned with the clamp 
yoke (Item 22)*. 

12.   Securely tighten the front cover 

plate screws.

13.   Turn AUTO/SET-UP switch to the AUTO position.

NOTE: Anytime blade adjustments are made, it is helpful to 

back out the blade set screws.

3.  Remove the front 

cover plate. For 
better access, dis-
connect the air line 
leading to the face 
plate by pushing in 
red ring on connec-
tor.

4.  Install the matched die type blades behind the 

appropriate wire guides. Note that  blade pairs have 
been carefully matched and should remain as a set. 
DO NOT MIX BLADES. Blades should be mounted 

with the etched “HA” part 
numbers facing outwards 
on both halves. The 3-digit 
serial numbers face inward. 
Knife-type blades are not 
serialized and can be locat-
ed with beveled surface 
facing either direction. 
Insure that both male and 
female blade halves are of 
the same part numbers.

110

HA2202

HA2202

110

FACE PLATE

Summary of Contents for Stripmaster 950

Page 1: ...45 950 45 954 45 950 1 Stripmaster Model 950 Model 954 Wire Stripper...

Page 2: ...y 4 Strip Length 5 Service Replacement Adjustment 6 Replacement Guide 7 Adjustments Clamp Stop 7 Adjustments Partial Strip 7 Circuit Board Adjustment 8 Stripmaster Model 950 950 1 Alignment Adjustment...

Page 3: ...ries not recommended by IDEAL Technical Data Strip Lengths Minimum 125 inches 3mm Maximum 63 inches 16mm Strip Capacity Minimum 30 AWG 05mm2 Maximum 10 AWG 6 0mm2 Accuracy Meets Military specification...

Page 4: ...locate the regulator in the mounting bracket and replace the retaining nut securely Thermal Head Rotation Speed 4 Connect the air line to a clean dry regulated air supply Air pressure must be regulate...

Page 5: ...ength turn machine to its upright position and turn power switch on Strip several sample wires and verify proper strip lengths Repeat strip length adjustments as required CAUTION Strip length range is...

Page 6: ...ly adjusted tighten all blade holding screws 10 Reconnect air line to the face plate by inserting hose into the com pression fitting firmly 11 Reinstall front cover plate making sure clamp dowel pins...

Page 7: ...e place use 7 64 hex wrench 3 Raise or lower set screws evenly use 1 16 hex wrench This will allow for an increase or decrease in the gripping force of the bush ings 4 Replace face plate NOTE One clam...

Page 8: ...crewdriver Clockwise to increase delay and counterclockwise to reduce delay 3 Cycle the machine and continue to readjust as required 4 Replace top plate It may be desired to increase the time delay af...

Page 9: ...raise or lower all six blades to their proper vertical position if needed Adjust both sides evenly 4 Install slug tray and top plate Adjustment Horizontal 1 Remove slug tray 2 Close blades using set u...

Page 10: ...t screws use 3 32 hex wrench reposition the carriage left or right to obtain the proper alignment 4 Install slug tray Adjustments Permanent Faceplate Clamp Bar 1 With air connected to machines turn po...

Page 11: ...cle n Empty the slug removal tray and make sure that all slugs have been removed from the unit n Disconnect the unit from the air and power supply and check to see that no insulation slugs are trapped...

Page 12: ...sed with each wire type and size Due to varying outside diameter dimensions on every wire IDEAL recommends ordering multiple wire guide bushings to match a given wire Depending upon wire tolerances it...

Page 13: ...2472 16 6 TRIGGER ASSEMBLY LB1526RP 17 5 SCREW 4 40 X 25 PH NYLON 358 033 ITEM REQ NAME PART NO 18 4 WASHER 4 NYLON 637 006 19 1 CONTACT PLATE LB1504 20 1 CUT YOKE K 6806 21 1 SLUG TRAY ASSEMBLY K 711...

Page 14: ...Notes...

Page 15: ...Notes...

Page 16: ...rington Cheshire WA5 5TN England 44 1925 444 446 www idealind com Warranty limited solely to repair or replacement no warranty of merchantability fitness for a particular purpose or consequential dama...

Reviews: