Resistance and Low Voltage Resistance
Measurements (Ohms)
Resistance
Resolution
Accuracy
Accuracy
Range
(61-633)
61-635)
400
Ω
10m
Ω
±(0.5% +2)
±(0.3% +2)
4k
Ω
100m
Ω
40k
Ω
1
Ω
400k
Ω
10
Ω
4M
Ω
100
Ω
±(0.5% +4)
±(0.3% +4)
40M
Ω
1k
Ω
±(5.0% +5)
±(5.0% +5)
Low Voltage
Resistance Accuracy
Accuracy
Range
Resolution
(61-633)
61-635)
4k
Ω
100m
Ω
±(1.0% +2)
±(0.6% +2)
40k
Ω
1
Ω
400k
Ω
10
Ω
4M
Ω
100
Ω
±(1.0% +4)
±(0.6% +4)
40M
Ω
1k
Ω
±(7.0% +5)
±(7.0% +5)
• Open circuit voltage:
3.3V
• Open circuit low voltage: 0.6V
• Input protection:
600V rms
16