Ideal Logic Combi E - 

User’s

 

Legend

A. 

Blank

B. 

DHW Temperature Control

C. 

CH Temperature Control

1

 

BOILER CONTROLS

Operation

Winter conditions - i.e. CH and DHW required.

Ensure the mode knob control (D) is set to winter (   ) 
The boiler will fire and supply heat to the radiators but will give 

priority to DHW on demand.

Summer conditions - i.e. DHW only required.

Set the mode knob control to Summer (  ). 
Set the CH external controls to OFF.
The boiler will fire whenever there is a demand for DHW.

Note

. The pump will operate briefly as a self-check once every 24 

hours, regardless of system demand.

Control of water temperature

Domestic Hot Water

The DHW temperature is limited by the boiler controls to 

64

o

C maximum at low draw-off rate, adjustable via the DHW 

temperature control (B).

Due to system variations and seasonal temperature fluctuations 

DHW flow rates/temperature rise will vary, requiring adjustment 

at the draw off tap : the lower the rate the higher the temperature, 

and vice versa.

Central Heating

The boiler controls the central heating radiator temperature to a 

maximum of 80

o

C, adjustable via the CH temperature control (C).

The Logic Combi E is a high efficiency combination boiler which is 

most efficient when operating in condensing mode.
The boiler will operate in this mode if the CH temperature control 

(C) is set to the ‘e’ position (economy mode).  This control should 

be set to maximum for very cold periods

To shut down the boiler

Set the mode knob control to OFF

To relight the boiler

Repeat the procedure detailed in ‘To light the boiler’.

Frost protection

If no system frost protection is provided and frost is likely during 

a short absence from home, leave the heating controls (if fitted) 

at a reduced temperature setting. For longer periods, the entire 

system should be drained.
If the system includes a frost thermostat then, during cold 

weather, the boiler should be turned OFF at the time switch (if 

fitted) ONLY. The mains supply should be left switched ON, with 

the boiler thermostat left in the normal running position.

Boiler Overheat Protection

The boiler controls will shut down the boiler in the event of 

overheating.  Should this occur, a fault code   will be displayed.
Refer to fault chart.

Flame Failure

Should this occur a fault code 

 will be displayed. Refer to fault 

chart.

G

H

A

B

E

F

C

D

J

Approx. flow temperatures for the boiler thermostat settings are:
 

Knob Setting 

Flow Temperature

 

Minimum

 40

o

C

 (104

o

F

)

 

Maximum

 64

o

C

  (147

o

F

)

D.

  Mode Control

E. 

Boiler Status

F. 

Burner ‘on’ Indicator

G. 

Pressure Gauge

H. 

Condensate Drain

J. 

Economy Mode

continued . . . . . . 

207763-1.indd   67

21/09/2011   10:15:04

Summary of Contents for LOGIC Combi E

Page 1: ...use only spare parts that you can be assured conform to the safety and performance specification that we require Do not use reconditioned or copy parts that have not been clearly authorised by Ideal...

Page 2: ...with the above regulations In IE the installation must be carried out by a Registered Gas Installer RGII and installed in accordance with the current edition of I S 813 Domestic Gas Installations the...

Page 3: ...efficient when operating in condensing mode The boiler will operate in this mode if the CH temperature control C is set to the e position economy mode This control should be set to maximum for very c...

Page 4: ...ced at least once a year by a Gas Safe Registered Engineer or in IE a Registered Gas Installer RGII Loss of system water pressure The gauge G indicates the central heating system pressure If the press...

Page 5: ...eck the time settings on the programmer are as you require and adjust if necessary Check the programmer internal or external to the boiler is in an ON position and the room thermostat is turned up NO...

Page 6: ...ral heating but the appliance has reached the desired temperature set on the boiler The boiler has a call for hot water but the appliance has reached the desired temperature set on the boiler The boil...

Page 7: ...Pressure ACTION Check system pressure is between 1 1 5bar on the pressure gauge If the boiler fails to operate then please contact Ideal if under warranty or alternatively a Gas Safe Registered Engin...

Page 8: ...tion No London 322 137 Ideal Stelrad Group pursues a policy of continuing improvement in the design and performance of its products The right is therefore reserved to vary specification without notice...

Reviews: