30
-
Installation & Servicing
INSTALLATION
39 ADVANCED CONTROLS ACCESS CONT'D
Press
Display
Factory
Setting
Upper
Limit
Lower
Limit
Description
DHW Temperature (ºC)
Instant water heater
40
65
Storage tank
20
70
60
P A R A
1. 6 0
2. 0 1
CH System
00 = Off
01
01 = On
02 = Off + pump continuous
03 = On + pump continuous
3. 0 1
DHW System
00 = Off
01
01 = On
02 = Off + pump continuous
03 = On + pump continuous
CH flow temperature (ºC)
20
90
82
Lowest CH flow temperature (ºC)
When using outside temperature sensor compensation
15
60
20
4. 8 2
. 2 0
. - 0 5
Highest outside temperature (ºC)
Than can influence temperature compensation
15
25
20
. 2 0
Lowest outside temperature (ºC)
That can influence temperature compensation
-20
10
-5
. - 0 2
Outside temperature correction (ºC)
For boiler reading of outside temperature
-01
05
00
. 0 0
Outside temperature (ºC)
At which frost protection starts
-30
10
-02
1
2
3
4
5
6
7
8
9
P05 appears
for 1 second
P06
P07
P08
P09
Minimum CH flow temperature (ºC)
Which will enable a CH request to be satisfied, when using
01
60
25
outside temperature compensation.
note 00 = Off
. 2 5
10
P10
Booster time (minutes)
01
30
00
note 00 = Off
. 0 0
11
P11
CH flow parallel shift
00
80
10
For use with outside temperature sensor
. 1 0
12
P12
Maximum fan speed CH (hundreds)
W45
55
W60
55
W80
Do not
Do not
59
W45P
adjust
adjust
50
W60P
49
W80P
57
. 5 9