11 FITTING THE FLUE SYSTEM
The maximum total equivalent lengths are given in
Table 7 and Table 8 for co---axial pipes ø 60---100 mm,
Table 9 for co---axial pipes ø 80---125 mm and in the
diagrams for the ø 80 mm twin pipes air---flue systems.
Refer to the assembly instructions contained within the
chosen flue kit packaging for the correct assembly and
installation.
Condensate Collection
When a length of vertical pipe is used in the system and the
length of flue exceeds the following, a condensate drain and
trap must be fitted to the lowest point of the system.
The trap must be connected to a suitable waste pipe.
ø80---125mm co---axial pipes --- 3 metres
ø80 twin flue pipes --- 7 metres
Flue Restrictors
Two different sized restrictors are supplied with the
europa 224, europa 228 boilers.
A 44 mm size is fitted to the boiler and a 47 mm size is
supplied in a separate bag.
Two different sized restrictors are supplied with the
europa 232 boiler.
A 47 mm size is fitted to the boiler and a 50 mm size is
supplied in a separate bag.
The appropriate restrictor, when necessary, must be fitted in
the flue outlet elbow as indicated in following picture.
For the correct use of the restrictors
with co---axial pipes
ø 60/100 mm refer to:
Table 7 for models
europa 224
,
europa 228
,.
Table 8 for model
europa 232
For the correct use of the restrictors
with vertical roof kit
ø
80/125 mm refer to:
Table 9 for models
europa 224
,
europa 228
Table 10 for model
europa 232
.
Table 7 --- Models europa 224, europa 228,
Pipe length (ø 60/100)
Restrictor
Between 0,3 (11.8“) and 1 m (39“)
ø 44 mm
More than 1 m (39“) up to 2 m (78.5“)
ø 47 mm
More than 2 m (78.5“) up to 4 m (157“)
no restrictor
Table 8 --- Model europa 232
Pipe length (ø 60/100)
Restrictor
Between 0,3 (11.8“) and 1 m (39“)
ø 47 mm
More than 1 m (39“) up to 2,7 m (8’ 10“)
no restrictor
Table 9--- Models europa 224, europa 228,
Pipe length (ø 80/125)
Restrictor
Between 0,5 (19.5“) and 1,5 m (59“)
ø 44 mm
More than 1,5 m (59“) up to 6,5 m (21’ 4“)
ø 47 mm
More than 6,5 m (21’ 4“) up to 8,5 m
(27’ 10“)
no restrictor
Table 10 --- Model europa 232
Pipe length (ø 80/125)
Restrictor
Between 0,5 (19.5“) and 4 m (13’ 1“)
ø 47 mm
More than 4 m (13’ 1“) up to 6 m (19’ 8“)
no restrictor
For the correct use of the restrictors
with twin pipes
refer to
the following diagram for the models
europa 224
,
europa
228
.
0.0
1.0
2.0
3.0
4.0
5.0
6.0
7.0
8.0
9.0
10.0
11.0
12.0
13.0
0.0
1.0
2.0
3.0
4.0
5.0
6.0
7.0
8.0
9.0
Flue exhaust (m)
Air intake (m)
europa 224
europa 228
Restrictor
47 mm
Allowed values
Refer to the following diagram for the model
europa 232
.
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
0
1
2
3
4
5
6
7
8
9
10 11 12 13 14 15 16
Flue exhaust (m)
Air intake (m)
europa 232
Restrictor
50 mm
No
Restrictor
Allowed values
IN
S
T
A
L
L
A
T
IO
N